background image

 

- 7 - 

Power supply connector

 

L : Line 

 

 

 

P1 : 

Filtration pump relay neutral (option) 

N : Neutral   

 

 

P2 : 

Filtration pump relay line (option) 

: Ground  

 

 

HR : 

Electrical heater contact (option) 

For three phases connections, L1 / L2 / L3 are used for phases. 

 Use the cable glands and grommets provided inside the heat pump to route cables. 

Since this machine is installed outdoors, connections must be made with a polychloroprene cable or with standard 

cables routed in protective conduit.  

The electrical cables must be buried in pliable electrical conduit (red) at a depth of 50 cm (85 cm under a roadway 

or path). When an underground cable conduit crosses another cable or other utility (water, gas…), they must be 
separated by a distance of at least 20 cm (8”). 

Heat pump power supply must be protected by a system in conformity with local laws. 

Heating priority 

It is possible to connect the water filtration pump to the heat pump, in order to start the filtration pump if the water is 

not at desired temperature. 

To connect the heating priority you need a normally open relay (contactor) with 230V AC coil. 
 

Wiring connections: 

 

Connect the relay coil (A1 and A2) with the terminals P1 and P2 of the heat pump 

 

Connect the relay in and out of the normally open contact in parallel with the relay of the filtration pump timer 

 
Wiring diagram: 
 

   

 

 

 

 

 

 
 
 

Filtration pump timer 

 

 

Relay (dry contact) 

 

Connection board heat pump 

 
Parameter to confirm heating priority: 

Check if the setting of heating priority (parameter #9) is set to 1. 
If not, please contact our hotline. 

Summary of Contents for INVERTER M

Page 1: ...Handbook Tebas Inverter 20 1 Angielska docx Inverter ...

Page 2: ...ion 5 Installation conditions 5 Hydraulic connections 6 Electrical connections 6 Heating priority 7 Utilization 8 Water connection 8 Regulation digital controller 9 Water flow setting 12 Winter setting 12 Water quality 13 Heating 13 Temperature rise phase 13 Maintaining the temperature 13 Maintenance by a qualified technician 13 After Sales Technical Service 14 ...

Page 3: ...8 hours The heat pump referred to in this handbook is designed and built solely for private swimming pool use Tebas dissociates its responsibility if used in any other application This handbook is considered as a part of the pool heat pump It must be read and adhered to before the installation and use of the appliance All security instructions highlighted in this manual must be strictly respected ...

Page 4: ...th automatic start up fan Cutting edges evaporator In order to avoid accidents prevent close access the appliance by children and pets Never cover the appliance whilst in operation and never put your fingers or other objects inside Never turn on the appliance with any of its panels removed Pressure controller Tebas heat pumps are provided with HP pressure controller set at 38 Bar Utilization limit...

Page 5: ...et side of the fan on a completely free space Make sure that the discharged air will not be sucked back into the evaporator again Provide enough space to allow access to temperature controller To improve your installation Avoid directing the flow of ventilated air towards a noise sensitive area room window for example or a space where people normally gather the discharged air will be cold Avoid po...

Page 6: ...ed on the floor or the walls so the heat pump will not support the weight of the water inside the plumbing Do not use a clamp or other tool to screw the connections hand screwing is sufficient Electrical connections Electric supply voltage and current values must correspond to the ones indicated on the heat pump Connection cables must to be sized according to the appliance power and installation r...

Page 7: ...ty water gas they must be separated by a distance of at least 20 cm 8 Heat pump power supply must be protected by a system in conformity with local laws Heating priority It is possible to connect the water filtration pump to the heat pump in order to start the filtration pump if the water is not at desired temperature To connect the heating priority you need a normally open relay contactor with 23...

Page 8: ...temperature is between 15 and 30 C 50 F and 86 F You can then start up your machine Follow the instructions below in the given order each time you start up the pool heat pump especially at the beginning of the swim season Open the three by pass valves and then half close the settings valve Start the pool pump Turn on the pool heat pump with the on off switch turn it to I Check the machine to make ...

Page 9: ...e the machine manage its power and keep low noise low speed Heats the water up to the desired value 1 C Smart Heating mode machine manage it s power for best efficiency Heats the water up to the desired value 1 C Boost Heating mode the machine manage its power and keep high power Heats the water up to the desired value 1 C Eco Cooling mode the machine manage its power and keep low noise low speed ...

Page 10: ...e Adjust the desired value with or and wait a few seconds till it is stored automatically Working information 3 symbols at the left bottom corner indicate the working information First symbol indicate the water flow Second indicate the fan Third indicate the compressor During the start time delay the corresponding symbol will blink Symbol indicates that the machine is defrosting Symbol indicates t...

Page 11: ...water flow switch position Contact your seller AL10 AL11 HP error AL15 AL16 Too much temperature difference between water in and water out AL18 Comp Out temp Too high AL17 Low temp protection in cooling mode AL7 AL8 Communication error Check electrical connection between controller and electronic card inside the machine AL3 Probe error Water in Check probe connection AL4 Probe error Water out AL5 ...

Page 12: ...12 C by pass setting is correct between 10 and 15 C Abnormal pressure If the pressure is too high or too low it indicates that the water flow circulating inside the heat pump is not correct You need to adjust the water flow by opening or closing the by pass valve Open little by little it if the pressure is too low and close it little by little if the pressure is too high until it remains stable in...

Page 13: ...ends on the exposure of swimming pool to wind sun and the pool environment as well as the heat pump size Maintaining the temperature Once the set temperature is reached you may reduce the filtration period according to the temperature requirements 8 to 10 hours a day minimum during the summer The heat pump will re start automatically when necessary The minimum working time depends of the season co...

Page 14: ...ormation together with the dimensions of the swimming pool your personal details address telephone number and the description of the failure If this procedure is respected the Tebas technician will be able to make as accurate diagnostic of the failure The recommended solution made by Tebas will be implemented briefly after that IMPORTANT If this measure is not followed warranty will be cancelled C...

Reviews: