Ask your electricity provider if necessary. 

If the electricity provider can not adjust it, it could translate into a tension reduction on the power supply for few 

seconds when the heat pump starts up. 

 Maximum water pressure : 2 bars (29 PSI). 

Installation 

Installation conditions 

Installation location 

 The pool heat pump must be installed outdoors with a distance greater than 2 m from the Pool according to 

laws in force (NF C 15 100). 

Install the pool heat pump on a flat, horizontal, and stable surface. (Concrete base would be ideal). 

Maintain at least 1 m (40

”) / minimum 30 cm (12”) of space on the rear (evaporator air inlet) and minimum 3 m (120”) 

on the outlet side of the fan on a completely free space. 

 

Make sure that the discharged air will not be sucked back into the evaporator again. 

Provide enough space to allow access to temperature controller. 

To improve your installation 

Avoid directing the flow of ventilated air towards a noise sensitive area (room window for example), or a space where 

people normally gather (the discharged air will be cold) 

Avoid positioning the pool heat pump on a surface that can transmit vibrations. 

Try  to  avoid  placing  the  appliance  under  a  tree  or  exposed  to  water  or  mud,  which  would  be  likely  to  complicate 

performance and maintenance. 

For best performance the water pipes from the heat pump to the pool should be insulated, especially if the heat pump 

is far away from the swimming pool. 

 

 

Outlet air flow: 

Open space / minimum 3 m (120 ”) 

Inlet air flow: 

1 m (40 ”) / minimum 30 cm 

(12”)  

Summary of Contents for INVERTER M

Page 1: ...Handbook Tebas Inverter 20 1 Angielska docx Inverter ...

Page 2: ...ion 5 Installation conditions 5 Hydraulic connections 6 Electrical connections 6 Heating priority 7 Utilization 8 Water connection 8 Regulation digital controller 9 Water flow setting 12 Winter setting 12 Water quality 13 Heating 13 Temperature rise phase 13 Maintaining the temperature 13 Maintenance by a qualified technician 13 After Sales Technical Service 14 ...

Page 3: ...8 hours The heat pump referred to in this handbook is designed and built solely for private swimming pool use Tebas dissociates its responsibility if used in any other application This handbook is considered as a part of the pool heat pump It must be read and adhered to before the installation and use of the appliance All security instructions highlighted in this manual must be strictly respected ...

Page 4: ...th automatic start up fan Cutting edges evaporator In order to avoid accidents prevent close access the appliance by children and pets Never cover the appliance whilst in operation and never put your fingers or other objects inside Never turn on the appliance with any of its panels removed Pressure controller Tebas heat pumps are provided with HP pressure controller set at 38 Bar Utilization limit...

Page 5: ...et side of the fan on a completely free space Make sure that the discharged air will not be sucked back into the evaporator again Provide enough space to allow access to temperature controller To improve your installation Avoid directing the flow of ventilated air towards a noise sensitive area room window for example or a space where people normally gather the discharged air will be cold Avoid po...

Page 6: ...ed on the floor or the walls so the heat pump will not support the weight of the water inside the plumbing Do not use a clamp or other tool to screw the connections hand screwing is sufficient Electrical connections Electric supply voltage and current values must correspond to the ones indicated on the heat pump Connection cables must to be sized according to the appliance power and installation r...

Page 7: ...ty water gas they must be separated by a distance of at least 20 cm 8 Heat pump power supply must be protected by a system in conformity with local laws Heating priority It is possible to connect the water filtration pump to the heat pump in order to start the filtration pump if the water is not at desired temperature To connect the heating priority you need a normally open relay contactor with 23...

Page 8: ...temperature is between 15 and 30 C 50 F and 86 F You can then start up your machine Follow the instructions below in the given order each time you start up the pool heat pump especially at the beginning of the swim season Open the three by pass valves and then half close the settings valve Start the pool pump Turn on the pool heat pump with the on off switch turn it to I Check the machine to make ...

Page 9: ...e the machine manage its power and keep low noise low speed Heats the water up to the desired value 1 C Smart Heating mode machine manage it s power for best efficiency Heats the water up to the desired value 1 C Boost Heating mode the machine manage its power and keep high power Heats the water up to the desired value 1 C Eco Cooling mode the machine manage its power and keep low noise low speed ...

Page 10: ...e Adjust the desired value with or and wait a few seconds till it is stored automatically Working information 3 symbols at the left bottom corner indicate the working information First symbol indicate the water flow Second indicate the fan Third indicate the compressor During the start time delay the corresponding symbol will blink Symbol indicates that the machine is defrosting Symbol indicates t...

Page 11: ...water flow switch position Contact your seller AL10 AL11 HP error AL15 AL16 Too much temperature difference between water in and water out AL18 Comp Out temp Too high AL17 Low temp protection in cooling mode AL7 AL8 Communication error Check electrical connection between controller and electronic card inside the machine AL3 Probe error Water in Check probe connection AL4 Probe error Water out AL5 ...

Page 12: ...12 C by pass setting is correct between 10 and 15 C Abnormal pressure If the pressure is too high or too low it indicates that the water flow circulating inside the heat pump is not correct You need to adjust the water flow by opening or closing the by pass valve Open little by little it if the pressure is too low and close it little by little if the pressure is too high until it remains stable in...

Page 13: ...ends on the exposure of swimming pool to wind sun and the pool environment as well as the heat pump size Maintaining the temperature Once the set temperature is reached you may reduce the filtration period according to the temperature requirements 8 to 10 hours a day minimum during the summer The heat pump will re start automatically when necessary The minimum working time depends of the season co...

Page 14: ...ormation together with the dimensions of the swimming pool your personal details address telephone number and the description of the failure If this procedure is respected the Tebas technician will be able to make as accurate diagnostic of the failure The recommended solution made by Tebas will be implemented briefly after that IMPORTANT If this measure is not followed warranty will be cancelled C...

Reviews: