background image

 

Sayfa 

5

 / 

22

 

 

*  The  pellet  stove  can  operate  in  conjunction  with  the  existing  multiple  chimneys.  In 
addition, the stove should not be connected at places such as the aspirator chimney and 
ventilator.  

* Product needs to be connected to the chimney with a shortest distance.   

* Always check the water level in the stoves and radiators with the manometer before 
the first installation (1 - 1.5 bar range).  

* The central heating boilers and stoves cannot be used without water. Our company is 
not responsible for damages caused by running without water.  

*  In  order  to  get  better  heat  efficiency  and  extend  the  life  of  the  product,  qualitative 
pellet and wood fuel should be preferred. Do not use moist or wetted pellet, sawdust, 
coal etc.  

* Since the pellet stoves are designed according to the interior spaces and give heat to 

the  environment,  they  should  not  be  installed  in  places  such  as  bathrooms,  shelter, 
cellar.

 

4.3 INSTALLATION AND CONNECTION 

 

* Installation must be done by an authorized person. Pellet stoves or boilers are fully 

automatic products. Expansion vessel, circulation pump, thermostates, safety valve and 

safety switches are readily installed inside the product. Ignition is made by a resistance 
and fuel is fed by an auger.

 

4.3.1 Electricity 

The electricity must be 230V / 50 Hz. Our company is not responsible for any damage 

that  may  occur  in  case  of  any  voltage  drop  or  rise.  We  recommend  taking  necessary 
measures as it does not include the warranty. 

 

 

4.3.2 Sanitary 

It is recommended that the radiator installation connection needs to be carried out by 

an  authorized  person  for  regular  and  comfortable  operation.  Our  company  is  not 
responsible for any damage related to the installation.  

After the safety precautions and precautions described above, the pellet stove or boiler 

can  be  installed  up  to  last  a  few  radiators  without  using  too  many  elbows  with  the 

installaton  line  pipes  1  "-  3/4"  METAL  or  PVC  pipes.  In  this  way,  the  hot  water  will 

circulate more easily and the temperature in the radiators is felt in a short time. 1/2 " 

METAL or PVC pipes can be used. The installation of the main pipes to the pellet stove 
should  be  securely  connected  to  the  radiators  by  using  the  fittings  as  shown  in  the 

diagram  (Gland,  nipple,  valve).  After  the  connection  is  done  the  system  will  be  filled 

with  water  by  the  authorized  person.  After  the  installation,  the  leakage  in  the 

Summary of Contents for TPW-23

Page 1: ...Installation and User Manual Pellet and Wood Central Heating Stoves Model TPW 23 Tested according to DIN EN 14785 For efficiency and emission see enclosed declaration of conformity TR...

Page 2: ...8 5 2 MAIN DISPLAY AND BUTTONS 10 5 3 MENUS AND SYMBOLS 11 5 4 ERROR CODES AND EXPLANATIONS 11 5 5 MENU FUNCTIONS 13 5 5 2 Combustion menu 13 5 5 3 Combustion management 14 5 5 4 Manual loading 14 5 5...

Page 3: ...ty and extend its life You can properly protect the fuel and the environment Warranty of the product depends on the right use of installation and instructions as described in the guide We recommend yo...

Page 4: ...related to combustion efficiency and flue gas emissions The product mentioned in this manual has been tested by the approved bodies according to EN 14785 Standard The packaging of the stove protects...

Page 5: ...safety valve and safety switches are readily installed inside the product Ignition is made by a resistance and fuel is fed by an auger 4 3 1 Electricity The electricity must be 230V 50 Hz Our company...

Page 6: ...ion The pellet stove can operate in conjunction with the existing multiple chimneys In addition the stove should not be connected at places such as the aspirator chimney and ventilator The chimney can...

Page 7: ...fire regulations and chimney s instructions must be complied For any related questions please ask the chimney installer Minimum distances to be observed in flammable or heat sensitive materials eg fur...

Page 8: ...Minimum distances for flammable materials and furniture are indicated on the product label and must not be exceeded If the floor where the stove needs to be installed is flammable or heat sensitive yo...

Page 9: ...ped to the left The active ones are displayed in green inactive in black The main screen will be accessed when scrolled down This screen is displayed in the Summer Winter Menu combustion management an...

Page 10: ...ired days INFO SCREEN When this symbol is touched information such as flue outlet temperature and water temperature is displayed IGNITION RESISTANCE When the symbol is green it indicates that the igni...

Page 11: ...e and exit menu Return to the previous menu Exit menu without saving 5 4 ERROR CODES AND EXPLANATIONS NOTE If you recieve an Error Code please check the related parts and the values After you solve th...

Page 12: ...eneral cleaning time is reached Please clean all the parts of the product Er07 Chimney emission fan motor error Check that your chimney is not clogged Reset the product by pressing P1 button for 3 sec...

Page 13: ...pellet and then continues with wood PELLET POWER This section contains the Power 1 6 and Auto options options where the combustion power of the fuel is selected WOOD POWER AUGER CALIBRATION Auger men...

Page 14: ...n Touch button to exit menu The summer mode is not used 5 5 4 Manual loading This menu is used to transmit the fuel from the fuel storage to the fire pot This will be activated by touching the symbol...

Page 15: ...e menu you will see the following screen Tap Daily Weekly or Weekend to select the desired timing interval The inactive time range will be gray To enter and edit the mode press symbol When it is in Da...

Page 16: ...ct the working day we want by scrolling the screen When we touch the opening and closing hours the screen will be displayed Set the desired hours from the Start and Stop section on the left with press...

Page 17: ...eek Ash drawer cleaning Daily Combustion pot cleaning Daily Oven bottom and top cleaning Twice a year Oven cleaning Once a year 6 1 FLAME PIPES CLEANING Remove the metal plate on the product s upper t...

Page 18: ...NG Carefully open the lid of the product so that the ashes are not spilled out clean them with a vacuum cleaner see picture 2 Make sure that the electricity is turned off and that it to stove is cold...

Page 19: ...G AND OVEN SECTION CLEANING The oven section needs to be cleaned once a year First the oven door and then the oven section must be removed In order to remove the cover the hinges must be removed by ha...

Page 20: ...Sayfa 20 22 In order to remove the oven section after the cover the screws and the oven section must be removed After the dismantling these sections should be cleaned with a wire brush...

Page 21: ...he oven frame when installing the compartment screws To clean the oven top the cleaning cap metal part in the products upper table be removed and cleaned with the help of a brush twice a year In order...

Page 22: ...oduct our company will try to repair this damage as soon as possible within the warranty period or it will replace the problematic part Only spare parts approved or supplied by the manufacturer must b...

Reviews: