Sayfa
5
/
22
* The pellet stove can operate in conjunction with the existing multiple chimneys. In
addition, the stove should not be connected at places such as the aspirator chimney and
ventilator.
* Product needs to be connected to the chimney with a shortest distance.
* Always check the water level in the stoves and radiators with the manometer before
the first installation (1 - 1.5 bar range).
* The central heating boilers and stoves cannot be used without water. Our company is
not responsible for damages caused by running without water.
* In order to get better heat efficiency and extend the life of the product, qualitative
pellet and wood fuel should be preferred. Do not use moist or wetted pellet, sawdust,
coal etc.
* Since the pellet stoves are designed according to the interior spaces and give heat to
the environment, they should not be installed in places such as bathrooms, shelter,
cellar.
4.3 INSTALLATION AND CONNECTION
* Installation must be done by an authorized person. Pellet stoves or boilers are fully
automatic products. Expansion vessel, circulation pump, thermostates, safety valve and
safety switches are readily installed inside the product. Ignition is made by a resistance
and fuel is fed by an auger.
4.3.1 Electricity
The electricity must be 230V / 50 Hz. Our company is not responsible for any damage
that may occur in case of any voltage drop or rise. We recommend taking necessary
measures as it does not include the warranty.
4.3.2 Sanitary
It is recommended that the radiator installation connection needs to be carried out by
an authorized person for regular and comfortable operation. Our company is not
responsible for any damage related to the installation.
After the safety precautions and precautions described above, the pellet stove or boiler
can be installed up to last a few radiators without using too many elbows with the
installaton line pipes 1 "- 3/4" METAL or PVC pipes. In this way, the hot water will
circulate more easily and the temperature in the radiators is felt in a short time. 1/2 "
METAL or PVC pipes can be used. The installation of the main pipes to the pellet stove
should be securely connected to the radiators by using the fittings as shown in the
diagram (Gland, nipple, valve). After the connection is done the system will be filled
with water by the authorized person. After the installation, the leakage in the