background image

 Cont. Summary of Configuration Variables

>

  DCC compatible accessory decoder

 Control switches (turnouts)

 Drive switch status LEDs

 Drive low current switch machines

 Eight configurable routes

 16 Individually configurable inputs & outputs

 Featuring “Smart” Programming

>

  DCC gateway to serial bus

>  LocoNet

® 

compatible

TEAM DIGITAL

WARNING:

This product contains a chemical known to the state of

California to cause cancer, birth defects or other reproductive harm.

16

03.28.11   V16
LocoNet is a registered
trademark of Digitrax Inc

TEAM DIGITAL, LLC

3111 Timber Valley Dr

Kokomo IN 46902

www.teamdigital1.com

CV#

Function/Default Value

CV#

Function/Default Value

173  Route 3 Cell 7 Address Adder

0

215  Route 6 Cell 4 Address Adder

0

174  Route 3 Cell 8 Address

0

216  Route 6 Cell 5 Address

0

175  Route 3 Cell 8 Address Adder

0

217  Route 6 Cell 5 Address Adder

0

176  Route 4 Cell 1 Address

0

218  Route 6 Cell 6 Address

0

177  Route 4 Cell 1 Address Adder

0

219  Route 6 Cell 6 Address Adder

0

178  Route 4 Cell 2 Address

0

220  Route 6 Cell 7 Address

0

179  Route 4 Cell 2 Address Adder

0

221  Route 6 Cell 7 Address Adder

0

180  Route 4 Cell 3 Address

0

222  Route 6 Cell 8 Address

0

181  Route 4 Cell 3 Address Adder

0

223  Route 6 Cell 8 Address Adder

0

182  Route 4 Cell 4 Address

0

224  Route 7 Cell 1 Address

0

183  Route 4 Cell 4 Address Adder

0

225  Route 7 Cell 1 Address Adder

0

184  Route 4 Cell 5 Address

0

226  Route 7 Cell 2 Address

0

185  Route 4 Cell 5 Address Adder

0

227  Route 7 Cell 2 Address Adder

0

186  Route 4 Cell 6 Address

0

228  Route 7 Cell 3 Address

0

187  Route 4 Cell 6 Address Adder

0

229  Route 7 Cell 3 Address Adder

0

188  Route 4 Cell 7 Address

0

230  Route 7 Cell 4 Address

0

189  Route 4 Cell 7 Address Adder

0

231  Route 7 Cell 4 Address Adder

0

190  Route 4 Cell 8 Address

0

232  Route 7 Cell 5 Address

0

191  Route 4 Cell 8 Address Adder

0

233  Route 7 Cell 5 Address Adder

0

192  Route 5 Cell 1 Address

0

234  Route 7 Cell 6 Address

0

193  Route 5 Cell 1 Address Adder

0

235  Route 7 Cell 6 Address Adder

0

194  Route 5 Cell 2 Address

0

236  Route 7 Cell 7 Address

0

195  Route 5 Cell 2 Address Adder

0

237  Route 7 Cell 7 Address Adder

0

196  Route 5 Cell 3 Address

0

238  Route 7 Cell 8 Address

0

197  Route 5 Cell 3 Address Adder

0

239  Route 7 Cell 8 Address Adder

0

198  Route 5 Cell 4 Address

0

240  Route 8 Cell 1 Address

0

199  Route 5 Cell 4 Address Adder

0

241  Route 8 Cell 1 Address Adder

0

200  Route 5 Cell 5 Address

0

242  Route 8 Cell 2 Address

0

201  Route 5 Cell 5 Address Adder

0

243  Route 8 Cell 2 Address Adder

0

202  Route 5 Cell 6 Address

0

244  Route 8 Cell 3 Address

0

203  Route 5 Cell 6 Address Adder

0

245  Route 8 Cell 3 Address Adder

0

204  Route 5 Cell 7 Address

0

246  Route 8 Cell 4 Address

0

205  Route 5 Cell 7 Address Adder

0

247  Route 8 Cell 4 Address Adder

0

206  Route 5 Cell 8 Address

0

248  Route 8 Cell 5 Address

0

207  Route 5 Cell 8 Address Adder

0

249  Route 8 Cell 5 Address Adder

0

208  Route 6 Cell 1 Address

0

250  Route 8 Cell 6 Address

0

209  Route 6 Cell 1 Address Adder

0

251  Route 8 Cell 6 Address Adder

0

210  Route 6 Cell 2 Address

0

252  Route 8 Cell 7 Address

0

211  Route 6 Cell 2 Address Adder

0

253  Route 8 Cell 7 Address Adder

0

212  Route 6 Cell 3 Address

0

254  Route 8 Cell 8 Address

0

213  Route 6 Cell 3 Address Adder

0

255  Route 8 Cell 8 Address Adder

0

214  Route 6 Cell 4 Address

0

SRC16

Switch & Route Controller

Improving the
world of DCC

or 9 -12 V DC

use only with an
accessory bus

Summary of Contents for SRC16

Page 1: ...der 0 188 Route 4 Cell 7 Address 0 230 Route 7 Cell 4 Address 0 189 Route 4 Cell 7 Address Adder 0 231 Route 7 Cell 4 Address Adder 0 190 Route 4 Cell 8 Address 0 232 Route 7 Cell 5 Address 0 191 Rout...

Page 2: ...Variables CVs The throttle is used to issue switch or accessory commands just like con trolling switches turnouts Smart programming only works when connected to track power To program in Smart mode co...

Page 3: ...n release it The SRC16 is now ready to have the input and output group addresses changed Using the throttle select the switch address or accessory number you want for group 1 and issue a throw reverse...

Page 4: ...other programming tips see Team Digital s web site Reset the SRC16 to factory defaults To reset the SRC16 to factory defaults turn power on and wait until LED 1 turns off Then press the Smart button...

Page 5: ...utput is grounded The closed output is now at 5 volts so 5 volts is applied to the motor in the opposite direction Consequently it moves in the throw direction Since the SRC16 uses 5 volts for motor d...

Page 6: ...Bus communication Allows the SRC16 to communication with devices connected to the serial bus Option 6 DCC control Allows the SRC16 to receive instructions from DCC track Note Selecting this option DI...

Page 7: ...bar from the factory setting unless MotoDs are being used See sec tion 5 4 5 4 10 PIN Input and Output Input and output connectors have the same pin definitions Connections can be made using our term...

Page 8: ...ttles or computers matches the top address and switch state for that route When a route is executed turnout commands are sent for each cell containing an address Optionally a route can be executed by...

Reviews: