CENTERING DEVICE, RBK-X1
Rev. 1
Jan. 2021
.
Page 14
3.2 Setting to machine
1. Make sure the software of the machine is the latest. If not, click on below link to download the latest
program and update machine software (HMI & PLC).
2. Power ON machine and login on with authority B (password: 12345), access to Maintenance page.
Switch ON the below 2 icon.
i.
Centering Device switch. When it was showing ON, Centering Device is activated.
ii.
Turn on this icon while Centering Device activated, cycle can be run
automatically without press on both start button.
DON’T use this function for production, since
a
cycle start without hands on start button, operator could have chance to put hands into machine,
that may cause crushing.
3. Turn back to Main interface. Machine is ready for operation. Refer to document 409-35021, section
4.2.8 about how to operate the RBK-X1 with auto Centering function.