background image

409-35013 

Rev A 

of 8 

5.2.

 

Guard Insert Adjustment 

The DCCM guard insert is adjustable to align the guard insert window with the DCCM cut window and the 
applicator crimp area. To adjust the guard insert proceed as follows: 

1.  Open the main guard door and loosen the three screws that secure the guard insert. 

2.  Close the main guard door. 

3.  Align the vertical slot in the guard insert with the center of the DCCM cut window. 

If the DCCM unit was aligned correctly as described in Section 6.1 then centering the window of the 
guard insert with the cut window of the DCCM unit should center the guard with the crimping area of 
the applicator. 

4.  Hold the guard in the correct position and open the main guard door. 

5.  Tighten the two inside screws securing the guard insert, then tighten the outside screw. 

6.  Close the main guard door and double check the guard insert slot alignment. If adjustments are still 

required repeat necessary steps above. 

6.

 

TROUBLESHOOTING 

Contact the Support Center at 1-800-522-6752. 

7.

 

DISPOSAL 

Contact TE Connectivity (TE) for disposal. 

8.

 

REPLACEMENT AND REPAIR 

There are no customer-replaceable parts.  Call 1-800-522-6752 for customer repair service. 

9.

 

R

o

HS INFORMATION 

Information on the presence and location of any substances subject to Restriction on Hazardous Substances 
(RoHS) can be found at the following website: 

http://www.tycoelectronics.com/customersupport/rohssupportcenter/

 

Click on “Find Compliance Status" and enter equipment part number.

 

10.

 

REVISION SUMMARY 

This is the initial release. 

Summary of Contents for AMP 5K/30

Page 1: ...READ THIS FIRST 2 1 INTRODUCTION 3 2 DESCRIPTION 5 2 1 Functional Description 5 3 RECEIVING INSPECTION AND INSTALLATION 6 3 1 Receiving Inspection and Installation 6 3 2 Initial CQM Setup 6 3 3 Confi...

Page 2: ...t Never wear loose clothing or jewelry that may catch in moving parts of the equipment Never alter modify or misuse the equipment SUPPORT CENTER CALL TOLL FREE 1 800 522 6752 CONTINENTAL UNITED STATES...

Page 3: ...tions and requirements for the CE Terminating Machines with a DCCM installed that differ from the specifications and requirements of the standard machine are as listed below Weight 77 6 Kilograms 171...

Page 4: ...damage NOTE Highlights special or important information Always wear approved eye protection while operating the equipment Always wear approved hearing protection while operating the equipment Use cau...

Page 5: ...a pneumatically operated chopping blade that is mounted to the front of the terminator s base plate The DCCM cutting blade is actuated when the pneumatic solenoid connected to DCCM receives a signal...

Page 6: ...to be performed if the Use CQM option is not seen on the CQM screen when the machine is turned on 1 In the CQM Control Panel screen select System Setting and then select DCCM Installed pick 2 Turn th...

Page 7: ...the DCCM proceed as follows NOTE The applicator to be used in the machine must be installed in the machine prior to adjusting the DCCM or the machine guards Install the applicator in the machine acco...

Page 8: ...n the correct position and open the main guard door 5 Tighten the two inside screws securing the guard insert then tighten the outside screw 6 Close the main guard door and double check the guard inse...

Reviews: