409-35013
Rev A
8
of 8
5.2.
Guard Insert Adjustment
The DCCM guard insert is adjustable to align the guard insert window with the DCCM cut window and the
applicator crimp area. To adjust the guard insert proceed as follows:
1. Open the main guard door and loosen the three screws that secure the guard insert.
2. Close the main guard door.
3. Align the vertical slot in the guard insert with the center of the DCCM cut window.
If the DCCM unit was aligned correctly as described in Section 6.1 then centering the window of the
guard insert with the cut window of the DCCM unit should center the guard with the crimping area of
the applicator.
4. Hold the guard in the correct position and open the main guard door.
5. Tighten the two inside screws securing the guard insert, then tighten the outside screw.
6. Close the main guard door and double check the guard insert slot alignment. If adjustments are still
required repeat necessary steps above.
6.
TROUBLESHOOTING
Contact the Support Center at 1-800-522-6752.
7.
DISPOSAL
Contact TE Connectivity (TE) for disposal.
8.
REPLACEMENT AND REPAIR
There are no customer-replaceable parts. Call 1-800-522-6752 for customer repair service.
9.
R
o
HS INFORMATION
Information on the presence and location of any substances subject to Restriction on Hazardous Substances
(RoHS) can be found at the following website:
http://www.tycoelectronics.com/customersupport/rohssupportcenter/
Click on “Find Compliance Status" and enter equipment part number.
10.
REVISION SUMMARY
This is the initial release.