409-35009
Rev E
26 of 44
HV-20 Terminators
1. Power ON the system by turning on the
AC Disconnect
switch.
2. Navigate to the HV-20 diagnostic display (Figure 34).
Figure 20: Input identifiers for HV-20
OFF
ON
3. Close all the guards: Front Guard and Side Feed (if equipped).
4. On the diagnostic display, verify that the input identifier
Guards Sw.
is ON (Figure 20).
5. Open the Front Guard. Verify that the input identifier
Guards Sw.
is OFF.
6. Close all the guards: Front Guard and Side Feed Guard (if equipped).
7. On the virtual keypad display, verify that the input identifier
Guards Sw.
is ON.
8. Twist and pull out (to release) the
Emergency Stop
push button.
9. Press the
Safety Reset
push button.
10. Verify that the
Safety Reset
indicator in the
Safety Reset
push button turns ON when the button is
pressed.
11. Verify that the input identifier
E-Stop
is ON and that the input identifier
Inv. Safe Off
is OFF
12. Press the
Emergency Stop
push button.
13. Verify that the
Safety Reset
indicator in the
Safety Reset
push button turns OFF when the
Emergency Stop
push button is pressed.
14. Verify that the input identifier
E-Stop
is OFF and that the input identifier
Inv. Safe Off
is ON.
DANGER
If the preceding checks cannot be verified,
do not
operate the machine. Failure to verify these systems checks indicates a
potential problem with the safety system. Contact TE Field Engineering personnel for assistance.