409-35009
Rev E
23 of 44
Inspect the crimped terminal to verify that the terminal is being positioned properly within the applicator.
Correct for any positioning errors in accordance with the applicator instruction sheet.
Repeat steps 2 and 3 until a terminal is properly positioned.
Place a prepared wire in the crimp area and press the foot switch.
Inspect the completed crimp and adjust as needed.
4.7.
Adjusting the crimp height
Refer to the 408 series instruction sheet provided with the applicator to perform this adjustment. Refer to
on page 28 for procedures to adjust the crimp height using the machine precision adjustment
feature.
PREVENTIVE MAINTENANCE
Preventive maintenance will keep the machine in good working order and ensure maximum reliability and
service from all components.
DANGER
To avoid personal injury, electrical and pneumatic power must be
disconnected
at the source prior to maintenance.
DANGER
The AC motor drive maintains high voltage for a period of time after power has been removed. Disconnect the power source
and wait several minutes before opening the electrical enclosure.
5.1.
Cleaning
Clean any debris from the applicator area daily.
DANGER
Compressed air used for cleaning must be reduced to less than 207 kPa [30 psi] and effective chip guarding and personal
protective equipment (including eye protection) must be used.
If an air-feed assembly is installed, check and replace the air filter element, if necessary.
Wipe the guards with a soft, clean cloth.
CAUTION
Do not
use any solvent to clean the guards. Solvent can cause irreparable damage.