RBK-X1
PN 2234800-1
Page 29 Rev A Sept 2019
4.2 Operation
4.2.1
Stand-by mode
When turn on the main power switch, the I/O button LED start to flash,
machine is in stand-by, no power is connected to the
heater
,
fan
and
motor
circuits. Currently the machine is showing standby interface and
ready to power ON by press on I/O button for 5 second.
Processor can be set the time to entry standby mode automatically after no
action to the processor, in case of accident if operator is leaving.
I/O button
4.2.2
Single Process mode (Main Interface)
The process selection button parameters (time; temperature; product
size) have been assigned and stored for each process button. The
selected process button number and its stored parameter will be
shown on the main interface, and they can be used repetitively until
another process button is selected.
10X process quick buttons
.
4.2.3
Sequence Production mode
Allow operator to operate the production for different process step by
step according to the sequence which preset and stored in machine.
After operator complete current process, then it would jump to next
process automatically according the sequence preset in selected
sequence as cycle, unless quit the sequence production mode.
Operator can interrupt sequence or shift process if need, by press on
“SEQU” button.
Currently this machine can store 1#~15# sequence. 10 process for
each sequence.
4.2.4
Remote Operation mode
Allow the machine to receive and operate following the heating
parameter (product size/temperature/time), which transport from
Schunk welding machine through the RS232 Interface socket.