Figure 2 

5.

 

CRIMPING PROCEDURE 

The following procedure provides only general information concerning crimping.  Refer to instructional material 
packaged with the dies and power unit for more detailed information including wire stripping dimensions and 
how to position terminals or splices in the dies. 

CAUTION 

Never operate the power unit without having a crimping head attached to the handle control or crimping head coupling. 

 

1.  Insert a terminal or splice in the stationary die in accordance with instructions packaged with the dies. 

2.  Activate the power unit to advance the dies and hold terminal or splice in place. 

3.  Insert the stripped wire into the terminal or splice. 

4.  Activate the power unit to complete the crimp. 

6.

 

INSPECTION AND MAINTENANCE 

DANGER 

Verify hydraulic pressure is released and power supply is disconnected before following inspection and maintenance 
procedures, unless otherwise specified in the procedure. 

Each crimping head is assembled and inspected before shipment.  TE Connectivity recommends that the 
crimping head be inspected immediately upon its arrival at the facility of use, and at regularly scheduled 
intervals to ensure the head has not been damaged during handling and use.  Frequency of inspection 
depends upon the following: care, amount of use, and handling of the head; type and size of products crimped; 
degree of operator skill; and environmental conditions. 

 

 