Introduction 

EXpert

2

 is a two-door access control unit (ACU) 

that is administered by a computer (PC) running 
TDSi’s EXguard software. More than one controller 
can be administered simultaneously from one or 
more computers, and TDSi manufacture several 
controller types besides EXpert

2

 that can co-exist 

in a single system. 

The software is used to monitor events and to 
program ACUs with card numbers, access rules 
and other parameters such as input and relay 
functions. The software does not need to be 
running continuously, as ACUs hold all the 
information they need, to provide the security 
features that have been set up. 

For detailed installation instructions, please refer to 
the Installation Manual available from 

https://www.tdsi.co.uk

 
PC Communication 

 

 

 

Make a note of the 10-digit UID of the EXpert

2

 unit (this is visible through a window in the connection 

label). The UID is needed when you add the ACU details into the EXgarde database. For units 
connected via Ethernet, you also need to know the IP address. Once the required information has 
been entered, you can start (or re-start) EXgarde Communications and the computer will start 
communicating with the ACUs. 

Whether you are using serial (RS232 or RS485) or Ethernet (TCP/IP) communications, the quickest 
way of commissioning the installation is to run the 

xsearch

 application which is one of the tools 

available in the EXgarde Toolkit (see UM0062 EXgarde Toolkit User Guide for details). 

Dip Switches (RS485) 

Re-position the 5 dip-switches accordingly: 

 

Switch 1 should be OFF (down) 

 

Switches 2,3,4 & 5 provide RS485 end-of-

line termination. Termination is required 
when connecting multiple ACUs via 
RS485 from the IP-connected ACU. Only 
one set of termination switches should 
be on for the whole RS485 
communications line. 

 

When installing multiple ACUs, make a note of the 
UID number of each unit and its location. 

RS232 (to single EXpert2 unit) 

PC 9-way  PC 25-way 

EXcel 

Terminal 

Function 

Receive 

Transmit 

Ground 

RS485 (one or more units over RS485 
using EXcel or an EXpert) 

RS485 – 

Connected 

5002ACU 

RS485 – 

Connected 

ACU 

Function 

RS485A TX 

RS485B TX 

RS485A RX 

RS485B RX 

ACU Chassis 

ACU Chassis 

Protective screen 

 

 

 