background image

44

TDS

 Technical dive system ■ 4

www.cascoantiguo.com | 

www.tdsdive.com

1

ST

 Stage - 

2

ND

 Stage

 - Octopus

1. 

ALARMS AND GENERAL PRECAUTIONS

 

WARNING:

 Before using this regulator, you must have successfully received training 

and certification in the technique of autonomous scuba diving from a recognized training 
agency (or any military or government diving school). The use of DIVING equipment by un-
certified or unskilled persons is dangerous and can lead to serious injury or death.

 

WARNING:

 This regulator is not configured for commercial use as a surface supply 

with air.

 

WARNING:

  Always pressurize the regulator gradually by opening the bottle valve 

SLOWLY.

 

WARNING:

  NEVER lubricate any part of the regulator (particularly the O-ring that 

provides the seal between the bottle valve and the regulator) with lubricants.

 

WARNING:

 DO NOT apply any type of spray to the regulator. Doing so may cause 

permanent damage to certain plastic or rubber components.

 

WARNING:

  The factory-prescribed service for this regulator must be performed at 

least once a year by TDS, or a TDS-appointed technician, trained at the factory. Repairs, 
disassembly of service or adjustment of the 1st and 2nd stage should not be attempted by 
persons who are not factory trained and authorized by TDS.

 

WARNING:

 Do not use the 1st stage regulator as a carrying handle when lifting or 

transporting the bottle, as this can damage the regulator or valve of the bottle.

 

WARNING:

  When diving in cold water (below 10°C), you must have received training 

and certification in cold water diving techniques from a recognized training agency.

 

WARNING:

 TDS regulators are designed to be compatible for use only with normal, 

atmospheric compressed air (21% oxygen and 79% nitrogen) that complies with EN 12021. 
DO NOT attempt to use it with other gases, including pure oxygen or enriched air with an 
oxygen content greater than 21%. Failure to comply with this warning can result in serious 
injury or death due to fire and explosions, serious deterioration, and equipment failure. The 
GULL and TAC BLACK models can be used with NITROX up to 40%.

Summary of Contents for OCEANUS

Page 1: ...INSTRUCTIONS USER S MANUAL 1ST STAGE 2ND STAGE OCTOPUS DE S IGN B Y A ND F OR DI V E R S OCEANUS PROTEUS GULL Z TAC BLACK...

Page 2: ...d in Warnings Cautions and Notes that are accompanied by one of these symbols WARNING indicates a procedure or situation that if not avoided could result in serious injury or death to the user CAUTION...

Page 3: ...e dive verifications 8 3 3 Pressurize regulator 8 4 DIVING WITH THE REGULATOR 9 4 1 Use as octopus 9 4 2 Diving in cold water 9 5 AFTER THE DIVE 10 5 1 Removal of the regulator in the bottle 10 5 2 cl...

Page 4: ...The factory prescribed service for this regulator must be performed at least once a year by TDS or a TDS appointed technician trained at the factory Repairs disassembly of service or adjustment of the...

Page 5: ...equipment PPE As such it belongs to Category III in accordance with the above mentioned Directive NOTE This user manual has been approved by ITALCERT S r l Viale Sarca 336 20126 Milan ITALY Notified...

Page 6: ...er immersion to maintain optimal performance for years to come 2 1 PRODUCT DESCRIPTION Tds equipment is mounted as a complete regulator 1st 2nd stage and hose and as 1st and 2nd single stages Their na...

Page 7: ...e removed 2 Remove the protective cover of the bottle valve 3 With the bottle valve outwards release a small amount of air from the bottle by turning the steering wheel counterclockwise to open the va...

Page 8: ...IN connector 4 Place the regulator of the first stage near the valve of the bottle so that the LP hose of the second primary stage is routed on the right shoulder Screw the DIN connector of the first...

Page 9: ...le valve purge the regulator and replace the hoses 4 Check to make sure that the submersible pressure meter shows an accurate measurement of the air pressure inside the bottle at the time of loading a...

Page 10: ...your regu lator and all your accessories in a warm dry place 3 Perform all pre dive checks of your equipment in a hot and dry place even before going to the dive site 4 Avoid breathing through the re...

Page 11: ...zing the yoke screw 4 With the bottle valve out open the valve slightly to release a small burst of air and then close the valve immediately This will remove any moisture that may have entered the val...

Page 12: ...diaphragm and or internal valve CAUTION Do not press the purge button or loosen the int of the first stage if the regulator is submerged without pressure Doing so will allow moisture to enter and will...

Page 13: ...vi ronment for diving equipment due to high levels of chlorine and pH balancing chemicals that cause certain components to deteriorate rapidly Get service for your regulator at least once a year from...

Page 14: ...me also known as an octopus You will also see CE0426 This denotes the identification number of the notified body which has independently certified and examined its product A serial number usually cons...

Page 15: ...ath This warranty gives you specific legal rights You may have rights that vary from country to country Photographs and models in this manual lvaro Herrero mekanphotography Berta Felipe berta_uw TDS Q...

Page 16: ...16 16 TDS Technical dive system 16 www cascoantiguo com www tdsdive com 8 ANNUAL INSPECTION AND SERVICE REGISTRATION DATE DEALER TECHNICIAN S NAME REMARKS SEAL...

Page 17: ...17 1ST Stage 2ND Stage Octopus Instructions User s manual 17 NOTES...

Reviews: