As soon as possible after diving, the regulator should be rinsed completely with fresh water whi-
le connected to a bottle  and pressurized with air.

Rinsing alone, however, will not clean up the regulator sufficiently. In order to clean up the con-
troller as thoroughly as possible, TDS recommends:

1. 

Connect the regulator to a loaded SCUBA bottle, open the  bottle valve to pressurize the regu-

lator and fully immerse the first and second stages in a freshwater bath. 

2. 

After the regulator has been properly soaked, it is important to rinse it vigorously by rinsing 

the main spring cavity of the first stage regulator (only environmentally unsealed models), the 
second stage nozzle and the openings in the front cover of the second stage with a strong 
stream of water. This will remove salt and mineral deposits that were released during soaking.

  

WARNING:

 

If you use a garden hose to clean it, DO NOT use the high pressure jet as this could damage the 

diaphragm and/or internal valve.

  

CAUTION: 

Do not press the purge button or loosen the int of the first stage if the regulator is submerged 

without pressure. Doing so will allow moisture to enter and will require the regulator to be returned to an Authori-
zed TDS Technician for repair.

3. 

Properly disconnect the regulator and clean it as dry as possible. Take it into the first stage to 

make sure all remaining moisture drains from the second stages and accessories.

4. 

DO NOT leave the regulator exposed to direct sunlight for extended periods of time.

5. 

When the regulator is completely dry, store it in a box of clean or sealed equipment inside 

a plastic bag. Do not store it where you may be exposed to extreme heat or an electric motor, 
which produces ozone. Prolonged exposure to extreme heat, ozone, chlorine and ultraviolet rays 
can cause premature degradation of rubber parts and components.

6. 

Never store the regulator while it is still connected to the bottle valve.

 WARNING: 

Do not use any type of solvent or petroleum-based substance to clean or lubricate any part 

of the regulator. Do not expose any part of the regulator to aerosols, as some aerosol thrusters attack or degrade 
rubber and/or plastic components.

Summary of Contents for GULL Z

Page 1: ...INSTRUCTIONS USER S MANUAL 1ST STAGE 2ND STAGE OCTOPUS DE S IGN B Y A ND F OR DI V E R S OCEANUS PROTEUS GULL Z TAC BLACK...

Page 2: ...d in Warnings Cautions and Notes that are accompanied by one of these symbols WARNING indicates a procedure or situation that if not avoided could result in serious injury or death to the user CAUTION...

Page 3: ...e dive verifications 8 3 3 Pressurize regulator 8 4 DIVING WITH THE REGULATOR 9 4 1 Use as octopus 9 4 2 Diving in cold water 9 5 AFTER THE DIVE 10 5 1 Removal of the regulator in the bottle 10 5 2 cl...

Page 4: ...The factory prescribed service for this regulator must be performed at least once a year by TDS or a TDS appointed technician trained at the factory Repairs disassembly of service or adjustment of the...

Page 5: ...equipment PPE As such it belongs to Category III in accordance with the above mentioned Directive NOTE This user manual has been approved by ITALCERT S r l Viale Sarca 336 20126 Milan ITALY Notified...

Page 6: ...er immersion to maintain optimal performance for years to come 2 1 PRODUCT DESCRIPTION Tds equipment is mounted as a complete regulator 1st 2nd stage and hose and as 1st and 2nd single stages Their na...

Page 7: ...e removed 2 Remove the protective cover of the bottle valve 3 With the bottle valve outwards release a small amount of air from the bottle by turning the steering wheel counterclockwise to open the va...

Page 8: ...IN connector 4 Place the regulator of the first stage near the valve of the bottle so that the LP hose of the second primary stage is routed on the right shoulder Screw the DIN connector of the first...

Page 9: ...le valve purge the regulator and replace the hoses 4 Check to make sure that the submersible pressure meter shows an accurate measurement of the air pressure inside the bottle at the time of loading a...

Page 10: ...your regu lator and all your accessories in a warm dry place 3 Perform all pre dive checks of your equipment in a hot and dry place even before going to the dive site 4 Avoid breathing through the re...

Page 11: ...zing the yoke screw 4 With the bottle valve out open the valve slightly to release a small burst of air and then close the valve immediately This will remove any moisture that may have entered the val...

Page 12: ...diaphragm and or internal valve CAUTION Do not press the purge button or loosen the int of the first stage if the regulator is submerged without pressure Doing so will allow moisture to enter and will...

Page 13: ...vi ronment for diving equipment due to high levels of chlorine and pH balancing chemicals that cause certain components to deteriorate rapidly Get service for your regulator at least once a year from...

Page 14: ...me also known as an octopus You will also see CE0426 This denotes the identification number of the notified body which has independently certified and examined its product A serial number usually cons...

Page 15: ...ath This warranty gives you specific legal rights You may have rights that vary from country to country Photographs and models in this manual lvaro Herrero mekanphotography Berta Felipe berta_uw TDS Q...

Page 16: ...16 16 TDS Technical dive system 16 www cascoantiguo com www tdsdive com 8 ANNUAL INSPECTION AND SERVICE REGISTRATION DATE DEALER TECHNICIAN S NAME REMARKS SEAL...

Page 17: ...17 1ST Stage 2ND Stage Octopus Instructions User s manual 17 NOTES...

Reviews: