BEFORE USING THE POWER SUPPLY UNIT 

  Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical 

shock, damage to the unit or a fire hazard. 

   

WARNING and CAUTION 

z

 

Do not modify. 

z

 

Do not touch the internal components, they may have high voltage or high temperature. You may get       
electrical shock or burned. 

z

 

When the unit is operating, keep your hands and face away from it as you may be injured by flying debris in 
the event of a fault. 

z

 

This power supply is designed for use within an end product. Stick the WARNING label for users on the   
system equipment and notify in the system instruction manual. 

z

 

Never operate the unit under over current or short-circuit conditions for more than 30 seconds or outside its 
specified Input Voltage Range. Insulation failure, burning, smoke or other damages may occur. 

z

 

Confirm connections to input/output terminals are correct as indicated in the instruction manual. 

z

 

This power supply has a possibility for hazardous voltage to appear at output terminal depending on the type 
of failure. The outputs of these products must be earthed in the end equipment to maintain SELV. 

      If the outputs are not earthed, they must be considered hazardous and must not be made user accessible.       
       

  Note: CE MARKING

 

   

CE marking, when applied to the LS series products, indicates compliance with the Low Voltage Directive 

(2006/95/EC) in that it complies with EN60950-1. 

      DWG NO. : PA582-04-01-A 

APPD CHK  DWG 

 

 

 

Summary of Contents for LS25 Series

Page 1: ...stem equipment and notify in the system instruction manual z Never operate the unit under over current or short circuit conditions for more than 30 seconds or outside its specified Input Voltage Range Insulation failure burning smoke or other damages may occur z Confirm connections to input output terminals are correct as indicated in the instruction manual z This power supply has a possibility fo...

Page 2: ...V Output terminal 25A max terminal 5 V Output terminal 25A max terminal 6 Output voltage adjustable trimmer 7 Output monitoring indicator Green LED ON 2 Terminal connecting method z Input must be off when making connection z Connect FG terminal to ground terminal of the equipment z The output load line and input line shall be separated and twisted to improve noise immunity LS25 LS35 LS50 LS75 LS10...

Page 3: ...Current Please select suitable input switch and fuse rating in case of re input the power at high temperature 3 4 Over Voltage Protection OVP The OVP function will shutdown the output except for LS25 The input need to be removed for a few minutes and then re input for recovery of the output OVP setting is fixed and cannot be adjusted externally Note For LS25 OVP function will cause the output into...

Page 4: ... reverse voltage 3 8 Parallel Operation A Operation to increase the Output Current is not possible B Operation as a Backup Power Supply is possible as follows 1 Set the power supply output voltage higher by the amount of forward voltage drop VF of the diode 2 Please adjust the output voltage of each power supply to be the same 3 Please use within the specifications for output voltage and output cu...

Page 5: ... 1 5kVAC between input and FG chassis and 500VAC between output and FG chassis each for 1 minute When testing withstand voltage set current limit of with stand voltage test equipment at 20mA Output FG chassis 100mA The applied voltage must be gradually increased from zero to testing value and then gradually decreased for shut down When timer is used the power supply may be damaged by high impulse ...

Page 6: ...erating below Please do not use installation Method E where the PCB will be on the topside and heat will be trapped inside the unit In the following derating curve the maximum output current is denoted as 100 A Output Derating versus Ambient Temperature Convection Cooling LS25 3 3 Output Derating Vs Ambient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperature o C Load Mounting A...

Page 7: ...ient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperature o C LS35 3 3 5 12 15 24 36 48 Output Derating Vs Ambient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperature o C Mounting A D Mounting B C Load 50 40 65 70 Mounting A B D Mounting C Load 65 70 45 50 ...

Page 8: ...utput Derating Vs Ambient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperature C Load Mounting Mounting A B D C 70 70 60 45 Output Derating Vs Ambient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperature C Load Mounting Mounting A B D C 40 60 70 50 70 ...

Page 9: ...utput Derating Vs Ambient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperature C Load Mounting Mounting A B C D 50 70 45 40 Output Derating Vs Ambient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperature C Load Mounting Mounting C A B D 70 60 70 ...

Page 10: ...Output Derating Vs Ambient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperature C Load Mounting Mounting A B C D 50 70 30 40 Output Derating Vs Ambient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperature C Load Mounting Mounting A B C D 50 70 45 ...

Page 11: ...g LS100 3 3 5 12 15 24 36 48 NOTE LS25 LS35 LS50 LS75 LS150 series do not require Input Voltage Derating Output Derating Vs Ambient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperature C Load Mounting Mounting A B C D 70 70 40 Output Derating Vs Input Voltage 0 20 40 60 80 100 120 88 230 Vin VAC LOAD 115 264 ...

Page 12: ...es must be as thick and short as possible to make lower impedance z Noise can be reduced by connecting a film capacitor with 0 1uF capacitance across the load terminals z For safety and EMI considerations connect the FG terminal of LS series to mounting set ground terminal z The recommended wire type Recommended crimp type terminal MODEL Recommended Wire Recommended torque D MAX t MAX Mounting Pie...

Page 13: ...mum capacitance shown below Maximum external capacitance MODEL 3 3V 5V 12V 15V 24V 36V 48V LS25 10 000uF 5 000uF 2 000uF 1 000uF 500uF LS35 LS50 10 000uF 5 000uF 2 000uF 500uF LS75 LS150 10 000uF 5 000uF 1 000uF NOTE It is normal to hear audible noise from power supply under Dynamic Load operation or if the input voltage waveform is not sinusoidal 9 Warranty Condition This product is under warrant...

Reviews: