1. Features
(1) Withstand Voltage (IN-OUT 1.0kVAC or 1.5kVDC, 1min.)
(2) Remote ON/OFF Control (RC terminal)
(3) Adjustable Output Voltage, 95% to 110% of the Nominal
(Single Output Model only)
(4) Over Current Protection (120% approx. or more, Hiccup Type)
(5) EMI VCCI Class A (with an External Filter)
TDK-Lambda
Page 1 / 3
This document presents a basic usage of the CCG6 or CCG10 series. Please refer to the
for details.
2. Basic Connection
The CCG can operate by connecting as shown in the figure below,
only with an external DC fuse. (There is no built-in input fuse.)
Fuse current rating
8A max
4A max
2.5A max
CCG6/10-48-xxS/D
CCG6/10-24-xxS/D
CCG6/10-12-xxS/D
Model
Recommended Fuse Type : DC86V11CT series (SOC)
3. External Input Capacitor
The CCG can operate without external input capacitors. External
capacitor can reduce input ripple voltage and conducted
emission noise. So, please connect it in addition if necessary.
4. External Output Capacitor
5. Application Example Configuration
(a) Single Output by CCG-S
(b) Single Output by CCG-D
CCG6
CCG10
470µF
3.3V,5V
220µF
12V,15V
100uF
±12V,±15V
220µF
±12V,±15V
470µF
220µF
100uF
220µF
Model
Output
Voltage
Application
Configuration
Fig. 5-(a)
Fig. 5-(b)
Fig. 5-(c)
CCG
(Top View)
+Vin
-Vin
RC
The CCG can operate without external output capacitors.
But an external output capacitor can reduce output ripple noise
and spike noise. So, please connect it in addition if necessary.
The table below shows allowable maximum capacitive load.
C
DC Fuse
CCG-S
(Top View)
+Vout
-Vout
TRM
CCG-D
(Top View)
+Vout
-Vout
COM
C
Load
CCG-D
(Top View)
+Vout
-Vout
COM
3.3V, 5V, 12V, or 15V
Load
Load
C
Load
24V, or 30V
+/-12V, or +/-15V
(c) Dual Output by CCG-D
(d) Negative Output by CCG
(e) Non-isolated Output by CCG
CCG
(Top View)
+Vout
-Vout
+Vin
-Vin
RC
Primary GND
TRM
Load
Secondary GND
-3.3V, -5V, -12V, -15V,
-24V or -30V
(Non-Isolated)
CCG-S
(Top View)
+Vout
-Vout
+Vin
-Vin
RC
DC Fuse
TRM
CCG-D
(Top View)
+Vout
-Vout
+Vin
-Vin
RC
COM
DC Fuse
Load
Load
Load
Note) Please consider equivalent I^2 t Characteristics when
obtaining replacement fuse of DC86V11CT series.
(0V)
CCG6, CCG10
Quick Manual
(COM)
CCG
(Top View)
+Vout
-Vout
+Vin
-Vin
RC
Primary and Secondary GND
TRM
(COM)
Load
CCG
(Top View)
+Vout
-Vout
TRM
(COM)
+3.3V, +5V, +12V, +15V,
+24V or +30V
Vin
Vin
C
C
CCG
(Top View)
+Vout
-Vout
TRM
(COM)
Load
(f) Series Output by CCG