User Manual
Chapter 5 - Electrical Connections 27
5.3. The control section
5.3.1. The A313-XX control card
A3
13
XX
LED
Colour
D1
yellow Lit = drive power
Flashing = parameters changed but not saved
Off = attempting to change unmodifiable parameter in Run
D2
green Lit = Run command enabled and active
D3
red
Lit = drive in alarm state
Connector
PIN N°
C1
6
Programming key connector
C2
6
Keypad connector
C3
7
Control terminals
C4
3
Serial line terminals
S1
4
Slot for optional serial line
Jumper
Default
J5
0
Transforms analog voltage input into current input
J7
0
Links control card 0V to ground
Function
DVS
Function
Function
D1 D2 D3
C1
HIGH VOLTAGE (DC-link)
C2
OPTO-INSULATION BARRIER- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
C3
LOW VOLTAGE (motor side)
J5 - J7
S1
C4
Table 5.3.1.1: LEDs, jumpers and connectors on the A313-XX
Figure 5.3.1.1: The A313-XX control card