TCS QWL2040 Installation Manual Download Page 6

6

7

2800 Laura Lane • Middleton, WI 53562  

|

  800.288.9383  

|

  www.tcsbasys.com  

Building Automation Systems

6

7

Installation

Material List

•  QWL2040 Panel 
• 

External Power Supply

Wall Mounting

The Panel is designed for wall mounting using four #10 pan head screws. 

The unit MUST be powered down while mounting to the wall. 

When selecting a location to mount the Panel, be sure to allow space for cable connections. 

Locate the Panel away from excessive dust, heat sources, moisture or direct sunlight. The ideal environment is a server 

room. The temperature of the room should not exceed 77ºF (25ºC); good ventilation is mandatory to provide sufficient air 

cooling.

Wiring Access Port

The Panel comes with a one-inch wiring access port pre-drilled in the top of the unit. Drilling into the unit to add additional 

wiring access ports is at your own risk. Use caution when drilling into the unit; be sure to capture all metal shavings. 

The unit MUST be powered down while drilling into the unit.

Factory IP Network Address Configuration

The Panel is typically purchased pre-configured to customer-specific IP networks and no additional software configuration 

is required. If your Panel was purchased without pre-configuration, it will be shipped with DHCP client enabled. 
The IP network configuration page is accessible through a web browser via a computer, e.g., a laptop, that is physically 

connected to the unit with a standard RJ-45 Ethernet cable. Contact your network administrator to determine the local IP 

address (refer to the MAC address available on the product label).

Summary of Contents for QWL2040

Page 1: ...2800 Laura Lane Middleton WI 53562 800 288 9383 www tcsbasys com 202403 Building Automation Systems Building Automation Systems Installation Manual QWL2040 Panel Integrated Building Manager...

Page 2: ...et 14 No Communication with RS485 Ports COM 1 and 2 Ubiquity Time out or No Data 14 Gateway Configuration 16 Introduction to Gateway Configuration 16 Gateway Configuration Via Laptop 16 Gateway Config...

Page 3: ...installation of the unit Gateway Configuration Most Panels come with the Gateway preconfigured if your Panel was preconfigured by TCS you can skip this section However some customers order their Panel...

Page 4: ...nt being controlled by the relay EEMS Enterprise Energy Management System A system of computer aided tools used by operators of electric utility grids to monitor control and optimize the performance o...

Page 5: ...plication programs can exchange data TCP IP Transmission Control Protocol Internet Protocol A set of standardized rules that allow computers to communicate on a network such as the internet UI User In...

Page 6: ...es with a one inch wiring access port pre drilled in the top of the unit Drilling into the unit to add additional wiring access ports is at your own risk Use caution when drilling into the unit be sur...

Page 7: ...estart the unit Exterior views Cloud Connectivity Ethernet Port Connect an Ethernet cable to the Ethernet port on the side of the Panel Connect the other end of the cable to your network switch port a...

Page 8: ...to the inputs on Com Port panel or on the Serial Board adjacent to the Gateway see RS485 Controller Network Wiring Setup on page 10 USB Ports 1 4 As an option you can connect up to 64 RS485 controlle...

Page 9: ...owing components Ubiquity Cloud Gatewayr SLQ218 Lighting Controller SLQ100 Electrical Pulse Meter These components accept the following inputs SLQ218 Lighting Controller Eight dry contact digital inpu...

Page 10: ...rough the network On controllers with displays this can be done from the controller using its keypad and display by using TCS Insight software or by calling TCS Technical Support 800 288 9383 ext 2 TC...

Page 11: ...ors contact TCS Technical Support 800 288 9383 ext 2 Three Wire Network Wiring Follow this wiring diagram for all three wire systems this is common NOTES In the middle of the network all network wirin...

Page 12: ...ontrollers use the second RS485 port or additional QD1010 adapters 2 Each controller must use the same baud rate and be assigned a unique address Two Wire Network Wiring Follow this wiring diagram for...

Page 13: ...o a cell modem if utilized 4 Connect the power source to the QWL2040 Panel and apply power If your Panel was preconfigured by the TCS factory or another user it will automatically go online and contac...

Page 14: ...ollow polarity Make sure the A wire goes to the A terminal in all devices as well as the wires that go to B and REF terminals No LAN Link to the Internet Verify the network cable is connected correctl...

Page 15: ...ting the serial ports are operational is located inside the enclosure on the Ubiquity Cloud board If none of these lights are functioning Ubiquity Cloud is not coming online This could be because the...

Page 16: ...t is the customer s responsibility to configure a custom login and password Contact TCS Technical Support 800 288 9383 ext 2 for information on managing Gateway login credentials Gateway Configuration...

Page 17: ...lect a Network Polling Cycle Time for the Panel This is the time interval that the unit will poll the entire network of controllers on all ports You must select whether to allow caching the host name...

Page 18: ...elect the communications protocol being used on each port TCSbus is selected by default Baud Rate This is the data transmission speed on the network The Baud Rate must be the same selection for the po...

Page 19: ...ly assigned when communication is established MTU Adjustments Adjusting the MTU down may allow gateways to communicate with smaller TCP packet sizes This may be useful if you are using cell modems not...

Page 20: ...mation Commissioning Tools You can access a separate page containing various commissioning tools by clicking the Commissioning Tools button at the bottom of the Security Information page These tools p...

Page 21: ...on the right side of the Controller View title bar will refresh each controller s status System Commands This section describes how to set up system flags for the Panel Reboot Unit sets a flag which...

Page 22: ...22 2800 Laura Lane Middleton WI 53562 800 288 9383 www tcsbasys com Building Automation Systems 22 Gateway Configuration Command Line Interface Screens Gateway configuration Application options...

Page 23: ...23 2800 Laura Lane Middleton WI 53562 800 288 9383 www tcsbasys com Building Automation Systems 23 Gateway Configuration Proxy options Extended application options...

Page 24: ...ely be prompted to change your login credentials Ubiquity Cloud login screen Lighting Module Programming Channel Event Scheduling The lighting module is equipped with eight independent event channels...

Page 25: ...GND To use this input with a threshold and hysteresis Channel Power section to shut off lighting channels select the relevant lighting channels Enable AI2 Threshold checkboxes and enter a threshold an...

Page 26: ...l Time NOTE For non North American Daylight Saving Time set the manual DLS Day Light Saving Time Channel Occupant Override A good example of the use of this feature is to allow for a cleaning crew to...

Page 27: ...demand for that particular meter For each of the four SEQ100 meter inputs there are five selectable options 1 ELEC 1 PH Electric single phase meter 2 ELEC 3 PH Electric three phase meter 3 GAS Gas me...

Page 28: ...and is set to 1 PPR Value The value of the PPR is the number of pulses per 1 kWh 1 BTU 1 gallon minute For example one pulse per 1 kWh equals 10 pulses per 1 kWh so the PPR value is set to 10 Constant...

Page 29: ...nterface Card NIC 2 Ethernet cable Connection Setup Ethernet Cable Connect one end of the Ethernet cable to the Local Management Ethernet Port on the Panel see Power and Communication Connections on p...

Page 30: ...ange adapter options 3 On the Network Connections panel locate the Ethernet interface that is connected to the cable Right click on the item and select Properties Properties 4 On the Ethernet Properti...

Page 31: ...31 2800 Laura Lane Middleton WI 53562 800 288 9383 www tcsbasys com Building Automation Systems 31 Appendices TCP IPv4...

Page 32: ...ing Automation Systems 32 Appendices 5 On the Internet Protocol Version 4 TCP IPv4 Properties change the IP schema to IP Address 10 248 248 2 Subnet Mask 255 0 0 0 Default Gateway 10 248 248 2 DNS Bla...

Page 33: ...Systems 33 Appendices 7 Launch any web browser and type in the following address https 10 248 248 1 Device address 8 Depending on your browser s configuration you may get the following screen Privacy...

Page 34: ...ys com Building Automation Systems 34 Appendices 10 Click on the Proceed link to take you to the next screen Proceed screen 11 Enter the Login user name and password Login screen 12 Configure the Gate...

Page 35: ...ement Port on page 29 and wish to revert back to its previous configuration follow the steps below Windows 10 or Later 1 Search for Ethernet Settings and click the Open link Ethernet settings 2 On the...

Page 36: ...WI 53562 800 288 9383 www tcsbasys com Building Automation Systems 36 Appendices Properties 4 On the Ethernet Properties panel locate the Internet Protocol Version 4 TCP IPv4 Select that option then c...

Page 37: ...37 2800 Laura Lane Middleton WI 53562 800 288 9383 www tcsbasys com Building Automation Systems 37 Appendices TCP IPv4...

Page 38: ...utomation Systems 38 Appendices 5 On the Internet Protocol Version 4 TCP IPv4 Properties General tab 6 Click on the Obtain an IP address automatically radio button 7 Click on the Obtain DNS server aut...

Page 39: ...ct the cable to the monitor and to the Panel Gateway matching up the corresponding ends HDMI DP See Power and Communication Connections on page 7 Power on the monitor and switch to the proper input ba...

Page 40: ...Command Line Interface CLI by connecting a keyboard and monitor to the device See Appendix C Monitor and Keyboard on page 26 Hardware Internet Requirements You must provide a secondary Internet connec...

Page 41: ...mmends contacting your IT department before making any changes to the default settings Click on the green Update Application Info button beneath the RS485 Network Port Configuration section to save th...

Page 42: ...he QWL2040 Panel and reboot the device See Appendix C Monitor and Keyboard on page 26 2 Establish a connection to the CLI see Gateway Configuration via CLI on page 15 3 Skip past the setup questions u...

Page 43: ...43 2800 Laura Lane Middleton WI 53562 800 288 9383 www tcsbasys com Building Automation Systems 43 Appendices Failover URL Settings E port 2 mode settings...

Page 44: ...Insight software you will need Laptop PC running Windows 10 or later with an available USB port USB A to B Cable RS485 Cable QD1010 USB Converter wired networks OR QW1010a Converter wireless networks...

Page 45: ...e Insight software and select Install FTDI Driver Follow the installation instructions 5 Select the new COM port and click on the Open Port button 6 Click on the second Poll tab This will cause the so...