6
11/2012
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
Subject to technical changes.
FAX: +49 (0) 41 94/ 9 88 129
Mail: [email protected]
PI_PUK-uk 1 A
Installation
Notes
Flush-mount box
Guide the connection cable through the conduit within the flush-mount box and fix it with
suitable screws to the wall.
The profile of the front-door station should be flush with the underground.
Front-door station
Attach the front-door station with the encloses hexagon socket screws via the attach-
ment holes to the studs in the flush-mount box.
It must be observed that the screws are not over-tightened. This could cause the defor-
mation of the housing. Thus, it may be impossible to install or remove the loudspeaker
cover and the nameplate glass.
!
Do not, under any circumstances, seal the device with silicone! Condensed water must
be able to run and evaporate!
Connecting the lines
General information
!
Connect the lines with the enclosed small screwdriver to prevent damaging the device.
Please note,
do not place the lines in front of the LED, this would affect the name field illumina-
tion
please observe that no line will be clamped below the spacer at the backside of the
front-door station
Connecting
1. Strip the cable ends.
2. Connect the lines depending on the type of system and according to the wiring diagram.
Connecting with a screw terminal with 5 poles
The screw terminal with 5 poles to connect the front-door
station with the TCS:BUS is plugable.
Connect the TCS:BUS to a, b and P and if existing, connect a
relay for controlling a door opener (FAA1100-0600) to the
terminals R and P.
Attach the screw terminal at the backside of the front-door
station according to the marking.