PI_GB_PES_PDS_Art0015689_1v0.doc 4
10/2005
General notes on the cabling in TCS audio systems
The cabling depends on the building situation and is only limited by its length.
•
When selecting the cable length consider: the
loop resistance must not exceed max. 20
Ω
(ta-
ble)
•
To keep within the max. permissible loop resis-
tance the wire cross section can be doubled, i.e.
two lines are used for one wire (figure). The li-
nes must be twisted.
•
When using screened cables: connect the
screens to each other and connect on one side
to earth (b wire) on the power supply unit
•
Choice of line or star wiring
rt = red
gn
= green
bl = blue
br
= brown
ws = white
sw
= black
ge = yellow
Table: loop resistances
Cable cross section
Cable length
in m
0.6 mm²
0.8 mm²
Loop resistance
in
Ω
10
1.22
0.69
20
2.45
1.38
30
3.67
2.07
40
4.90
2.76
50
6.12
3.44
60
7.35
4.13
70
8.57
4.82
80
9.80
5.51
90
11.02
6.20
100
12.24
6.89
150
18.37
10.33
200
24.49
13.78
250
17.22
300
20.66
TCS TürControlSysteme AG
•
Geschwister-Scholl-Str. 7
•
39307 Genthin
Subject to change without notice.
Phone: +49 39 33 / 87 99 10
•
Fax: +49 39 33 / 87 99 11
•
www.tcs-germany.com