6
02/2015
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 4194 9881-188
Subject to technical changes.
E-Mail: [email protected], www.tcsag.de
PI_IVH3222-0140_uk 3 A
Technical data
supply voltage:
+24 V
±
8 % (power supply and control unit)
housing:
plastics, white
dimensions (in mm):
H 250 x W 100 x D 50/28 (with/without handset)
weight 410 g
acceptable ambient temperature:
0 °C …+40 °C
degree of protection:
IP30
input current:
I(a) = 0.2 mA, I(P) = 4 mA
max. input current:
I(Pmax) = 90
mA
video module
TFT color module
screen diagonal:
8.9 cm (3.5 inch)
resolution:
320 x 240 pixel, RGB
video signal input:
symmetric 1 Vss FBAS,
Video 6-wire technique necessary!
Installation
!
Attention!
Video indoor stations have to be (de-)installed only voltage-free!
!
Please ensure not to overtighten the screws when installing the lower cover on uneven
surfaces. Over tighten the screws might be deforming the lower cover. As a result the
upper cover cannot be snapped-on to the lower cover or the save contact between
lower and upper cover might be affected.
mounting height
For an optimum viewing angle we recommend a mounting
height of 1.6 meters (upper egde of the device over the
ground).
Install the lower cover
For placing the connection cables without any problems, a
flush-mounted socket must be installed behind the device.
Position the flush-mounted socket below the cable con-
duit.
Install the lower cover with at least three suitable
screws to the wall: Attachment holes accordingly to the
illustration to the wall (
A
) or on the flush-mount socket
(
B
).
Screws are not enclosed in the
delivery.
position
flush-mount
socket
A
Wall fixing
B
Fixing on the
flush-mount
socket