background image

05/2013 

13 

 

TCS TürControlSysteme AG, TCS Hotline Germany:

 

Subject to technical changes. 

FAX: +49 (0) 41 94/ 9 88 129  

  Mail: [email protected]

 

FIL1101 UK  1A 

mi 

Sound profiles 

ring 
tone  

ISH1030 

ISH3030 

SKYLINE 

  0 

alpha tone 1 

triad gong  

trumpet sax 

  1 

alpha tone 2 

melody 1 

bigben 

  2 

alpha tone 3 

alpha tone triple 

china 

  3 

alpha tone 4 

melody 2 

doorbell 

  4 

alpha tone 5 

alpha tone 1 

fanfare 

  5 

alpha tone 6 

horch 

horch 

  6 

gong tone single 

bigben 

bell 

  7 

gong tone double 1 

elise 

djingle 

  8 

gong tone double 2 

melody 3 

telephone modern 

  9 

gong tone triple 

gong special 

triad 

10 

alpha tone triple 

rondo 

rythm 

11 

gong tone gleich 1 

alpha tone 3 

telephone old 

12 

gong tone gleich 2 

cadence 

cavalry 

13 

acknowledgement tone*

 

14 

alarm tone 1*

 

siren 1* 

15 

alarm tone 2*

 

siren 2*

 

 

*  Sounds cannot be selected as ring tones by the user. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for FIL1101-0140

Page 1: ...TCS T rControlSysteme AG TCS Hotline Germany Subject to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de FIL1101 UK 1A mi Product information Signal Unit FIL1101 0140...

Page 2: ...figurations 8 Preset factory settings 9 Programming with IR remote control 9 Important notes 9 ATTENTION Change master code 10 Initiate programming 10 Parallel allocation to serial numbers 1 and 2 11...

Page 3: ...neral safety regulations for telecommunication systems according to VDE 0800 must be observed Inter alia separated conduit of heavy and low current lines minimum distance of 10 cm in case of a common...

Page 4: ...t housing plastics white dimensions in mm W 98 x H 98 x D 12 weight 100 g acceptable ambient temperature 5 C 40 C input current standby 2 wire operation I a 1 5 mA 3 wire operation I a 0 2 mA I P 1 3...

Page 5: ...L1101 Short description 39 different ring tones 3 different sound profiles ISH1030 ISH3030 Skyline can be adjusted via IR remote control optical call display via blue lighting bar call distinction for...

Page 6: ...er to place the lines without any prob lems and to prevent clamping the lines when snapping on the up per cover Loosen the screws of the con nection terminal and connect the lines according to the lab...

Page 7: ...r to both adjustment increments at the lower cover 1 2 Snap on the upper cover 2 Open the device 3 There is s a release opening at the under side of the device Insert a screw driver with ca 7 mm width...

Page 8: ...r internal call x x select ring tone for door call 1 AS less or equal audio AS threshold x x select ring tone for door call 2 AS less or equal audio AS threshold x x select ring tone for sub door call...

Page 9: ...ad factory setting via push button Attention When loading the factory settings the master code and all settings set by the user will be lost To press the push button factory setting use a suitable too...

Page 10: ...mming Authorisation via IR remote control Keystroke is acknowledged by the device with a brief button acknowledgement tone Note If the ring tone output is switched off the red LED goes OFF with the fi...

Page 11: ...l numbers 1 and 2 Initiate programming If not yet done Enter 11 SNo 1 12 SNo 2 SNo 1 and 2 0 to 999999 WE 0 If SNo 0 is entered parallel allocation is deactivated SNo serial number of the indoor stati...

Page 12: ...d WE 10 4 door call 2 AS less or equal audio AS threshold WE 10 5 sub door call 1 WE 7 6 sub door call 2 WE 8 7 sub door call 3 WE 9 8 sub door call 4 WE 11 ring tone 0 to 12 each in every sound profi...

Page 13: ...china 3 alpha tone 4 melody 2 doorbell 4 alpha tone 5 alpha tone 1 fanfare 5 alpha tone 6 horch horch 6 gong tone single bigben bell 7 gong tone double 1 elise djingle 8 gong tone double 2 melody 3 t...

Page 14: ...dio AS threshold WE 2 30 5 sub door call 1 WE 2 30 6 sub door call 2 WE 2 30 7 sub door call 3 WE 2 30 8 sub door call 4 WE 2 30 9 GFA call WE 1 30 flashing sequence 0 OFF 1 blinks fast 2 blinks 3 fla...

Page 15: ...is stored incorrect value has been entered A negative acknowledgement tone sounds when pressing the key The the red LED blinks fast for 3 s then blinks again Set audio AS threshold for call distinctio...

Page 16: ...stored incorrect value has been entered A negative acknowledgement tone sounds when pressing the key The the red LED blinks fast for 3 s then blinks again WE factory setting Change master code Initia...

Page 17: ...d A positive acknowledgement tone sounds the red LED is ON for 3 s Then the red LED blinks incorrect entry un known master code A negative acknowledgement tone sounds when pressing the key The red LED...

Page 18: ...t tone red LED is ON 3 switch ON ring tone output the last ring tone sounds red LED is OFF 4 decrease volume The ring tone selected last sounds with the decreased volume the new value is stored 5 incr...

Page 19: ...battery 7 Attach the cover Attention Because the risk of explosion the button cells must not be recharged Do not dispose batteries as ordinary domestic waste Batteries must be delivered to a collecti...

Page 20: ...tion point for electronic waste Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Warranty We offer a simplified processing in case of warranty for electrici...