background image

39 

Cleaning 

 

!

 

Avoid water from entering the device! 
Do not use any abrasive detergents! 

 

Clean the indoor station with a dry or slightly wet cloth. Remove stronger 
stains with a pH-neutral cleaner. 
 
 
 

Conformity  

 

Declarations of conformity for download under www.tcsag.de 
Downloads > Commercial information. 

 
 
 

Information on disposal  

 

The adjoining symbol shows that the device has to be disposed 
separately from domestic waste. The materials used are recycla-
ble. Please do help protecting our environment and dispose the 
device via a collection point for electronic scrap. 

 

 
Dispose the parts of the packaging in collecting tanks for card-
board and paper resp. plastics. 

 
 
 

Warranty  

 

We offer 

a simplified processing

 in case of warranty for electrician. 

  Please observe our 

standard terms and conditions of sale

, availa-

ble under www.tcsag.de > Downloads > Commercial information and 
enclosed in our latest catalogue. 

  Please contact us: 

[email protected]

. 

 
 

Summary of Contents for Carus Origo CAI2010

Page 1: ...Product information video indoor station Carus Origo CAI2000 CAI2010...

Page 2: ...e top shell 12 Open the device 12 Installation CAI2010 tabletop device 13 Put up the table rack 13 Cable assignment 14 Terminating resistor CAI2010 14 Install the device 14 Deinstall the device 15 Wir...

Page 3: ...ation volume 29 Set date and time of the image buffer 30 Set image parameter 31 Symbols in the live image 31 Set contrast brightness and color saturation 31 Reload factory settings 32 Select the camer...

Page 4: ...system installations must be in compliance with the general safety regulations for telecommunication systems according to VDE 0800 Including separated cable routing of high and low voltage lines minim...

Page 5: ...al numbers generate a different ring tone Programming the bell buttons of the front door station can be realised with the Service Device TCSK 01 and configoTM On Screen Display OSD The menu which is s...

Page 6: ...verview image button loudspeaker microphone navigation button UP navigation button DOWN call OFF button screen menu button LED indication green LED indica tion red door release button speech button fu...

Page 7: ...parameter standby or speech mode select parameter which you want to change call OFF button ring tone stopper end speaking when the device is configured for simplex communication with configoTM image...

Page 8: ...t and can be used as tabletop device The video indoor station CAI20x0 must be installed on a flush mounted wall outlet socket The space for cabling is limited within the device Max number CAI20x0 in 6...

Page 9: ...ic door call distinction per bell button four different ring tones acoustic door call distinction for two doors ring tone mute with optical indication OSD based max 10 internal calls and max 10 contro...

Page 10: ...te might be deformed Install the adapter plate For an optimal operation a mounting height of 1 6 m is recommended In order to connect the cables without any problems a flush mounted socket must be ins...

Page 11: ...nes without spare cable loop in the top shell directly to the terminals Thus the top shell can be snapped on without any problems and the connection lines will not get clamped Connect the lines accord...

Page 12: ...ere is a rectangular release opening at the bottom of the device 3 Insert a small screwdriver straight and with slight pres sure into this opening The screw driver must not be wider than 7 mm and thic...

Page 13: ...able as signment In delivery state the device is equipped with a terminating resistor be tween V1 and V2 Observe the notes for installation under the point ter minating resistor when installing a vide...

Page 14: ...r CAI2010 Observe when installing video tabletop devices The installation of the lines to the connection sockets must be realised star shaped and must NOT be looped through Noncompliance leads to a vi...

Page 15: ...ert a small screwdriver straight and with slight pressure into this opening The screw driver must not be wider than 7 mm and thicker than 2 mm Otherwise the top shell can be damaged The top shell can...

Page 16: ...16 Wiring diagram Connection diagram Set terminating resistor if the device is installed at the end of the TCS BUS video strand...

Page 17: ...the video wires V1 and V2 the polarity must be observed Proof the a b and P wire against each other on short circuit Switch on the main voltage Error detection and indication Errors are signalled opt...

Page 18: ...the configurator configoTM Note The AS addresses of the front door stations have to be assigned via the Service Device For detailed information see section Service information in the TCS Installer 5...

Page 19: ...hands free talking after internal call on off x determine video AS border and door call AS border x image activation in case of a floor call x allocate short message groups x image buffer FVM1000 is...

Page 20: ...vigation buttons UP and DOWN The OSD main menu can be activated when no live image is displayed and if the indoor station is in standby mode That means that no voice connection is established and no d...

Page 21: ...buffer automatic image recording activated green deactivated red ring tone selection for floor calls menu send internal call ring tone selection for sub ring tone 1 menu send control function ring to...

Page 22: ...on volume setting Only if image buffer is ON and function short message is activated Help function To simplify the operation of the device symbols are faded in in the upper right corner when calling u...

Page 23: ...he same serial number are sent al ternating One control function number is used for switching on and the other for switching off Via two different symbols which appear inde pendently in front of the l...

Page 24: ...the menu button Select the sym bol Send internal call Select the required call destination with the navigation but tons UP or DOWN Trigger a call by pressing the menu but ton A positive acknowledgeme...

Page 25: ...buffer time setting and delete image buffer can be seen in the main menu Note The automatic image storage is not activated Activate deactivate the automatic image storage Activation Press the menu but...

Page 26: ...the green LED does not blink Press the menu button The main menu is displayed Select the symbol image buffer to display the image Browse through all new stored imag es with the navigation buttons UP...

Page 27: ...take a few seconds If all stored images of the allocated serial number have been deleted in the FVM1000 or no stored images are available when a call comes in the information empty storage is displaye...

Page 28: ...lume 1 to 4 is displayed The adjusted ring tone sounds in the selected volume and is stored Ring tone selection Press the navigation button UP or DOWN to move to the symbol Ring tone selection e g for...

Page 29: ...e setting are dis played Press the navigation button UP or DOWN to change the value The set ting immediately has an effect on the established voice connection The value is stored in case of an interna...

Page 30: ...n by pressing the menu button The menu date is displayed The marked number can be changed with the navigation buttons UP or DOWN By pressing the menu button the ad justment of the parameter is closed...

Page 31: ...rom camera AS address e g with AS address 05 ring tone mute call diversion is activated or door release automatic activated automatic image storage is activated menu image buffer is activated only whe...

Page 32: ...ng video front door station is displayed Press the image button again to switch over to the next video front door station or camera Short messages The video indoor station CAI20x0 can receive short me...

Page 33: ...more short messag es have been received than can be stored the oldest message is overwrit ten automatically General information on the conduit in TCS video systems 6 wire operation 6 wire operation is...

Page 34: ...wer supply and control unit is to be used Table 1 loop resistances length of the line a b M P in m cable diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 71 20 2 55 1 43 30 3 83 2 14 40 5 10 2 86 5...

Page 35: ...video BUS is too low At many components of the video BUS e g FVY the transmission level can be adjusted Please see the product infor mation of the active transmission components The light intensity of...

Page 36: ...k if the number of allowable video indoor stations per strand was not exceeded The terminating resis tor at video distributors or video switches with looped through signal is not plugged correct ly Re...

Page 37: ...eo BUS are connected Eventually you have to readjust the level Multiple contours occur Image reflections occur so called ghost images due to open lines The video strand is not connected Please place t...

Page 38: ...ires of the video BUS are con nected Please check the correct connec tion of the connection terminal The video image turns white after a while Switching the supply voltage off and on again the signal...

Page 39: ...e has to be disposed separately from domestic waste The materials used are recycla ble Please do help protecting our environment and dispose the device via a collection point for electronic scrap Disp...

Page 40: ...line tcsag de Headquarters TCS T rControlSysteme AG Geschwister Scholl Str 7 39307 Genthin FON 49 3933 8799 10 FAX 49 3933 8799 11 E Mail info tcsag de www tcsag de www carus concepts com Subject to t...

Reviews: