TCS900004, Rev.4
07/12/2016
Check us out at
www.TCSmeters.com
Page 36
Reassembly of Meter
Reinstalling Packing Capsule & Front/Rear Covers
1)
Reinstall cover O
-
Rings on the front and rear of meter housing.
2)
Reinsert packing capsule into front cover of meter with retaining plate and tighten screws.
3)
When attaching front cover, align packing capsule blade with the slot on the blocking rotor sleeve.
Tighten all front cover screws.
4)
Attach rear cover and tighten all screws.
Reinstalling Counter Support & Adjuster Drive Shaft
1)
Position the counter support on the front side of meter and tighten all screws.
2)
Reinsert adjuster drive shaft into the support housing. Assure that adjuster face gear teeth
mesh completely with the packing capsule gear. The face gear and packing gear should mesh
snugly, but do
not overtighten as this will cause premature wear on the gears.
3)
Slide down the adjuster mounting bracket and tighten the screws.
1
2
3
4
1
2
3