TCS900004, Rev.4
07/12/2016
Check us out at
www.TCSmeters.com
Page 12
Start-Up Recommendations (CONTINUED)
Direction of Flow
The meter is set up at the factory for left to right flow. To change the meter for right to left flow, begin
by removing the screws (#9 on the Meter Assembly Breakdown) and the adjuster cover plate (#7) on the
front of the meter. Remove the screws (#1), the drive shaft retainer (#10), the drive shaft (#3), the
E
-
Ring (#4) and the face gear (#5). Reinstall the gear on the shaft with the gear teeth facing up. Snap
the E
-
Ring back into place to hold the gear in place. Reinstall the shaft, mating the face gear with the
drive gear of the packing capsule assembly. Reinstall the screw and cover plate. The meter will now be
set up for right to left flow. See Page 22 for a parts breakdown of entire meter assembly.
14)
When operating the meter with accessories, valves should be opened slowly to avoid a pressure
surge that can damage the meter or air eliminator. System pressures should be maintained below
70 PSI (4.9 BAR).
15)
Custody transfer metering systems must be calibrated by a regulatory agency before product can
be sold off the meter. Contact your local authorities for proper calibration.
16)
Strainers should be cleaned frequently as part of a regular maintenance schedule. Doing so
will ensure a clean system and long service life.
#4 E
-
Ring
#3 Drive Shaft
#1 Slotted Screws
#5 Face Gear
#10 Drive Shaft
Retainer
#9 Slotted Screw