background image

Contact TCRS at 440-658-2020

 

 

TABLE OF CONTENTS 

Page No.  Description 

Table of Contents                            

Safety Information                            

Technical Data Specifications          

Operator Control Panel                    

Operation and Service                      

Troubleshooting                                

Electrical Schematic                          

Electrical Panel Layout                

10 

Structural\Sheet Metal    

Summary of Contents for AH150TON

Page 1: ...150 TON AHU OPERATING AND SERVICE MANUAL STARTING S N AHU 150 22 00037 REV ...

Page 2: ...ONTENTS Page No Description 1 Table of Contents 2 Safety Information 5 Technical Data Specifications 6 Operator Control Panel 7 Operation and Service 7 Troubleshooting 8 Electrical Schematic 9 Electrical Panel Layout 10 Structural Sheet Metal ...

Page 3: ...that may cause product damage are identified in this publication TCRS cannot anticipate every possible circumstance that might involve a potential hazard The warnings in this publication and on the product are therefore not all inclusive You must not use this product in any manner different from that considered by this manual without first satisfying yourself that you have considered all safety ru...

Page 4: ...that is damaged or missing If a message is attached to a part that is replaced install a message on the replacement part General Hazard Information Attach a Do Not Operate warning tag to the start switch or controls before the unit is serviced or repaired Attach the warning tags to the unit and to the operator control station When appropriate disconnect the starting controls Do not allow unauthori...

Page 5: ...and components When using air for cleaning allow the machine to cool to reduce the possibility of fine debris igniting when redeposited on hot surfaces Fluid Penetration Always use a board or cardboard when you check for a leak Leaking fluid that is under pressure can penetrate body tissue Fluid penetration can cause serious injury and possible death A pinhole leak can cause severe injury If fluid...

Page 6: ...pt Rating 10KAIC Minimum Circuit Ampacity 40 AMPS Enclosure Type Type 3R Control 110V Control 12V DC Blower Motor WATTS 4400 WATTS x4 FLA 6 6 AMPS x4 Circuit Protection 10 AMPS Condensate Pump H P 1 150 HP FLA 1 AMP Circuit Protection 2 AMPS Control Transformer Rating 500 VA Primary Fuse ATDR4 Secondary Fuse ATDR4 DBA 20 76 DBA DBA 20 with Ducts 66 DBA Weight 3500 LBS Made in USA ...

Page 7: ...Contact TCRS at 440 658 2020 Operator Control Panel 6 ...

Page 8: ...hooting Caution must be taken when troubleshooting the electrical circuit and should only be performed by a trained service technician INDICATION POSSIBLE CAUSE CORRECTIVE ACTION Nothing operates Main power Control power Check voltage Check transformer and fusing Blower Fault Breaker tripped Motor failure Find cause reset breaker Verify 480V 3ph is present Verify 0 10VDC control voltage is present...

Page 9: ...Contact TCRS at 440 658 2020 8 Electrical Schematic ...

Page 10: ...Contact TCRS at 440 658 2020 Electrical Panel Layout 9 ...

Page 11: ...Contact TCRS at 440 658 2020 10 ...

Page 12: ... Contact TCRS at 440 658 2020 11 ...

Page 13: ... Contact TCRS at 440 658 2020 12 ...

Reviews: