Factory Test & Alignment Specification For MT56 Series (V1.0)
5
2. Factory Menu
Factory Menu is mainly used for factory production and satisfies various demands of customers. It covers
all indispensable functions during manufacture such as
Warm up
,
White Balance
,
Shop
,
NVM Reset
,
Power on mode, USB Clone
etc.
2.1 Accessing Way
a. When the
Factory hotkey
item of Factory Menu is disabled (
OFF
), press
Menu
button of remote
control, then select
Settings/Picture,
make sure the cursor stop on
Contrast
item submenu. Finally,
press
9
,
7
,
3
,
5
consecutively.
b. When the
Factory hotkey
item of Factory Menu is enabled (
ON,
you can see the flashing
Factory
Captions Info
on the lower left corner), press
Back
button of remote control.
Press RCU “
OK
” key to enter the submenu.
Press RCU “
Right
” or “
Left
” key to change the values.
Press RCU “
Right
” or “
Left
” key run the function.
Press RCU “
Back
” or “
Menu
” key exit the Factory menu.
Factory Captions Info:
While “
FactoryKey
” is enabled, there is some toggled display information relative to
MV
,
SV, ID, MID
, to
facilitate 100% quick screening without accessing to whatever else menu:
P
(Production/Factory mode flag)
MV
(Mboot SW Version)
SV
(Main SW Version)
ID
(Project ID)
MEMC
Summary of Contents for 55D1620
Page 35: ...2 No Display Black Panel Back light is OK sound is OK but no picture...
Page 37: ...4 No sound O ll i l i h d One or all signal source without sound...
Page 39: ...6 Abnormal Display OSD NG or picture NG OSD NG or picture NG...
Page 40: ...7 No tuning channels DTV or ATV no Channels DTV or ATV no Channels...
Page 42: ......