Field Wiring

KLCUL Field Wiring Connection Terminals

Compression type terminals are provided 

for all line wiring connections. The wire size 

capacity ranges and tightening torque for 

the power terminals are listed in the table. 

Warnings and Cautions

Dangerous Voltage Warning: warns of 

situations in which a high voltage can 

cause injury and/or equipment damage. 

The text next to this symbol describes 

ways to avoid danger.
General Warning: warns of situations 

that can cause physical injury and/

or equipment damage by means other 

than electrical. The text next to this 

symbol describes ways to avoid the 

danger.

General Safety Instructions

Be sure to read, understand, and follow 

all safety instructions.

Only qualified electricians should 

carry out all electrical installation and 

maintenance work on output filter.

All wiring must be in accordance with 

the National Electrical Code (NEC) 

and/or any other codes that apply to 

the installation site.

Disconnect all power before working 

on the equipment. Do not attempt any 

work on a powered output filter.

The KLC, VFD, motor, and other 

connected equipment must be properly 

grounded.

The VFD terminals and connected 

cables are at a dangerously high voltage 

when power is applied to the VFD, 

regardless of motor operation.

Warning

Warning

Warning

Warning

Warning

Warning

Warning

Warning

!

!

!

!

See www.transcoil.com for dimension tables

Please contact TCI Technical Support 

or your TCI distributor for application 

information regarding the use of KLC 

output filters on the output side of the VFD. 

KLCUL Model 

Numbers

Input and Output Motor Power

Wire Size

Torque 

(in. - lb.)

KLCUL2A to 

KLCUL12A

12 - 18

10

KLCUL16A to 

KLCUL55A

4 - 18

20

KLCUL80A

1 - 22

35

KLCUL110A to 

KLCUL130A

2/0 - 6

120

KLCUL160A to 

KLCUL200A

250 MCM - 6

275

KLCUL250A to 

KLCUL300A

600 MCM - 4 

Two: 250 MCM - 1/0

500

KLCUL360A

Two: 350 MCM - 4

275

KLCUL420A to 

KLCUL600A

Two: 600 MCM - 2

500

KLCUL750A

Two: 800 MCM - 300 

MCM

500