background image

TMN-5000i-V1

  

                     

TMN-5000i Hardware User Manual (Ver.1)

                                        

11 

  

  

  

 Appendix A 

 
TMN-5000i Interface Panel 

 

 

 
 
 
  
  

 

 

.  

 

 

P

o

wer

 Ja
c

k

 

 

RS

 4

8

5

 I

n

te

rfa

c

e

 

 

F

e

m

a

le

 A
n

te

n

n

a

 S
o

cke

 

In

p

u

0

 

In

p

u

1

 

In

p

u

2

 

In

p

u

3

 

Gr
o

u

n

d

 

In

p

u

4

 

In

p

u

5

 

In

p

u

6

 

In

p

u

7

 

Gr
o

u

n

d

 

 

 

RS

 2

3

2

 In

te

rfa

c

e

 

 

Ou
tp

u

t 0

 

Ou
tp

u

1

 

Ou
tp

u

2

 

Ou
tp

u

3

 

Ou
tp

u

4

 

Ou
tp

u

5

 

Ou
tp

u

6

 

Ou
tp

u

7

 

+12

V

 

Gr
o

u

n

d

 

 

 

Summary of Contents for TMAS TMN-5000i

Page 1: ...ll Rights Reserved This document TMN 5000i V1 contains information that is proprietary to TCAM Technology Pte Ltd No part of this document may be copied or reproduced in any form or by any means or transferred to any third party without prior written consent of TCAM Technology Pte Ltd The content of this document may be revised without prior notice ...

Page 2: ...s 6 6 Hardware Configuration 7 6 1 Step 1 Insert SIM Card 7 6 2 Step 2 Connect Backup Battery 8 6 3 Step 3 Connect Input Output I O 8 6 4 Step 4 Install Antenna 9 6 5 Step 5 Connect Programming Cable to PC 9 6 6 Step 6 Configure TMN 5000i on PC 9 7 Alarm Control and Output Control 10 7 1 I O Terminals 10 7 2 Alarm Control 10 7 3 Output Control 10 8 Appendix A 11 9 Technical Support 12 ...

Page 3: ...r mobile phone Users can also send SMS to control different output devices that are connected to the SMS Controller SMS Controller is designed to operate in standalone mode or in a network with other SMS Controller devices It can be scaled up and deployed on demand as many to one device or one to many devices Managing large scale of SMS Controller devices remotely is made easy with TMAS PC Manager...

Page 4: ...DC Power Adapter x 1 Input 100 240VAC 0 6A Output 12VDC 2A 4 Backup Battery x 1 Rechargeable lithium ion type 3 7V 2000mAH Comes with battery connector cable Can last for minimum 4 hours excluding external devices 5 Programming Cable x 1 DB9 female to RJ12 male converter 6 TMAS PC Manager Software See attached TMAS PC Manager Quick User Guide for the download link Figure 1 TMN 5000i Unit Figure 2 ...

Page 5: ...s or network login in progress 10ms ON 3990ms OFF Logged into the 3G network When TMN 5000i successfully logs into the network it will beep once Event LED OFF No input or output is triggered 500ms ON Input or output is triggered If second event occurs within less than 2 second after the first event LED will restart and keep LED on for another 2 seconds Alarm LED OFF No alarm is triggered ON Input ...

Page 6: ...ters Power Failure Battery Low Detection Yes I O Configuration Yes Normally Open or Close Toggle ON OFF Sub Node Inputs Expansion RS485 Max 16 TMN 10 modules for max 128 inputs Software Features Weekly Schedule 4 user defined schedules to alert users on different shifts User defined Message Yes max 40 characters Resend SMS Alert Yes resend by count and interval Back to Normal Alert Yes Alert Escal...

Page 7: ...irst time You may find a video guide online on our website s product page 6 1 Step 1 Insert SIM Card There are a total of 6 locks circled in red colour as shown below in the Figure 6 From the side groove shown below in the Figure 7 use a flat screwdriver to pry open the casing Figure 6 Bottom View of the TMN 5000i Figure 7 Prying from the Side Groove ...

Page 8: ...onnected to the TMN 5000i the backup battery is estimated to last for minimum 4 hours on standby You may locate a white coloured backup battery power socket as shown above in the Figure 8 and plug it with the battery connector cable 6 3 Step 3 Connect Input Output I O The input terminals work with 5V TTL or voltage free dry contact digital input All input channels can be configured by TMAS PC Mana...

Page 9: ...e power jack Then switch on the power adapter Check for connection to the 3G network When the network LED blinks once in every 4 seconds this indicates that your TMN 5000i has logged into the network Run the TMAS PC Manager software on your PC to configure your TMN 5000i For more information on configuration using the PC Manager Software please refer to the attached TMAS PC Manager Quick User Guid...

Page 10: ... alarm notification To trigger the output alarm state the output terminals are toggled by the input alarm state CMS or users via SMS 7 2 Alarm Control When an alarm is triggered the alarm LED is ON Alarm notification will only be sent to the designated users Maximum of 16 users will be notified If you have installed TMAS modem T61 EHS5 you will receive a SMS on your CMS To acknowledge the alarm pl...

Page 11: ...ndix A TMN 5000i Interface Panel Power Jack RS 485 Interface Female Antenna Socket Input 0 Input 1 Input 2 Input 3 Ground Input 4 Input 5 Input 6 Input 7 Ground RS 232 Interface Output 0 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 12V Ground ...

Page 12: ...ries please contact your local sales representatives or TCAM Technology Pte Ltd 2 Kaki Bukit Ave 1 05 04 Singapore 417938 Tel 65 67461930 Fax 65 67461938 Company Website https www tcam com sg For sales enquiries please email to enquiry tcam com sg For technical enquiries please email to support tcam com sg ...