T61 Smart Modem
Page 35 of 47
User Guide V1.4
7.3.7.3
IP Address Report
If this feature is enabled and the device will update its latest IP when it is available via either SMS or
DDNS update.
Boolean
0
Disable IP report function
1
Enable SMS report function. When device obtains a new IP it will send a SMS
to the
2
Enable IP DDNS update. When device obtains a new IP it will update its IP to
a DDNS server to update its domain name, T61AXXXXXXXX.tmas.com using
http protocol. Please contact TCAM Technology if you want this feature to be
enabled.
7.3.7.4
DDNS Server IP
This parameter defines the Dynamic Domain Name Server IP. T61 device will update its new IP
address to its DDNS host at this IP.
String
xxx.xxx.xxx.xxx
Server Address in IP form
7.3.7.5
User Phone Number
This parameter records the user who will receive alarm alerts. If it is left empty, no alert SMS will be
sent out.
String
9876541 (e.g.)
Phone number in the string form up to 19 characters. Country or area codes
are optional
7.3.7.6
Long Life Reset Interval (hr)
This parameter defines how frequent T61 device resets itself to avoid any malfunctioning.
Integer
0
Disable this reset mechanism (not recommended)
1-65535
Enable long life reset mechanism with specified interval in hours.
7.3.8
I/O Setup (Optional Feature)
This section defines the working mode of the digital input or analog input and digital output pin
availiable at the 4-pin micro-fit interface. If T61 is programmed into smart modem mode, user is able
to utilize the input and output functions with proper configuration. These functions are not available
when T61 is programmed as normal modem. In general, user is able utilize an input as real-time
analog reading port or an alarm trigger input. The digital ouptut of T61 can be control remotely by
SMS or command from SMS. This open collector output is capable of driving a circuit with maximum
rating of 1A and 48V. When the digital output is triggerd, it will connect the digital output pin to the
ground.
7.3.8.1
AI Monitor Setting
This parameter configures the analog input reading feature.