T61 Smart Modem
Page 30 of 47
User Guide V1.4
7.3.3.3
Packetization
There are three parameters defining the way T61 smart gateway packetizing the incoming data. The
benefit of packetizing data is to make sure that data received and sent out is wrapped within one
single packet. It becomes handy when end applications can only digest incoming data within one
single packet. The drawback of packetizing data is that it slows down the data transfer rate.
Max Packet Size (byte)
Integer
0-1200(default)-1450
Maximum number of bytes per packet.
Packet Idle Interval (ms)
Integer
0
Disable packetization and enable transparent mode
1-100 (Default)-65535
Inter-packet delay in milliseconds.
Packet End Character
String
Default setting is blank
Packet ending character. This string is a display of the hex value of Packet
End Character, i.e. the Packet End Character is 0x0D.
To configure the Data Line as a transparent communication channel and disable the packetization,
please change Packet Idle Interval to 0. As long as the Packet Idle Interval setting is not 0, all
incoming data will be packetized using an algorithm described below.
7.3.3.4
Login Password
This parameter defines the password required to enter T61 Configuration menus. The factory default
password is “tcam”, all in small letters. User can change this password upon first login or leave as
default.
String
tcam
This is the default password, user can change to another one with maximum
length of 8 bytes
7.3.3.5
Unique Device Name
This parameter is the same as the device name recorded in Center Manager if it is in use. It can be
configured to user defined device name or different serial number assigned by customers for
applications. This device name will be used for SMS alert.
String
Device Name
A name string up to 18 characters.