background image

EN

INSTALLATION GUIDE

TDCi-CH series isolated DC/DC chargers

WARNING

Please read this document very carefully to avoid DC/DC converter malfunction, equipment damage and/or fire hazards!

The TDCi-CH series are based on the standard TDCi products, but are equipped with an 
automa c ba ery charging func onality. This enables the possibility to charge a ba ery 
connected to the output from another ba ery connected to the input. The TDCi-CH models are 
galvanically isolated, which means that the input and output circuits are not electrically 
connected to each other.

Introduc on

Installa on

1) Check if the input voltage range of this model is compa ble with your DC source (ba ery or

2) The TDCi-CH must be mounted in a cool, dry indoor loca on
3) For models with 12V/20A output use 4mm² cable size for both input and output wiring.
     For models with 24V/10A output use 4mm² for input wiring and at least 2.5mm² for output
     wiring.
4) Always install fuses at the input and output. If no fuses are used then warranty is void
5) First connect the nega ve input and output to the corresponding nega ve input and output

     power supply)

     terminals of the converter. A en on: A bad nega ve connec on could make the output

7) Check if the output voltage of the unit meets the requirements of the ba ery to be charged.

     voltage equal to the input voltage!
6) Now connect the posi ve input cable, via a suitably rated fuse, to the posi ve input terminal

     When these requirements are met, you can now safely connect the ba ery to posi ve output
     terminal through a suitably rated fuse.

Specifica on & fuse ra ng table

Model

In/out isola on Vin range Input fuse

Vout

Iout Output fuse

TDCi-12/12-20CH

TDCi-12/24-10CH

TDCi-24/12-20CH

TDCi-24/24-10CH

9...18Vdc

20...35Vdc

35A

20A

14.4Vdc

28.8Vdc

14.4Vdc

28.8Vdc

20A

10A

20A

10A

25A

15A

25A

15A

Limitations of use: do not use in connection with life support systems or other medical equipment or devices. To be installed only by qualified technicians.

CAUTION

!

Declara on of conformity

Manufacturer
Address

declares that the following products:

Product type
Models

conforms to the requirements of the following EU direc ves:

: TBS Electronics BV
: De Marowijne 3
  1689AR, Zwaag
  The Netherlands

: DC/DC Charger
: TDCi-CH series

EMC direc ve 2014/30/EU
RoHS direc ve 2011/65/EU

Yes

TDCi-CH DC-DC Charger installa on guide Rev1en

When during the charge process the ba ery (output-) voltage has reached 14.2V 

(or 28.4V for 

24V output model)

, a  mer will start that will run for one hour. A er one hour, the converter will 

jump to the "Standby mode". In this mode the output voltage will be set to 13.7V 

(or 27.4V for 

24V output model)

 and both the yellow and green LEDs are lit.

- Or the input voltage drops below 11.8V (or 23.6V for 24V input model) for 5 minutes.

- The input voltage drops below 11.6V (or 23.2V for 24V input model) for 10 seconds.

- Or when the TDCi-CH has been in the "Standby mode" for 24 consecu ve hours.

During opera on in the "Charge mode" or "Standby mode", the TDCi-CH will automa cally jump 
to the "Off mode” when:

The TDCi-CH has three different modes: “Charge”, “Standby” and “Off”. Once connected, the 
converter will be in the “Off mode”. In this mode, the converter will output 0V and the yellow 
(input) LED will flash once per second. The green (output) LED is off.

- The output voltage drops below 13.2V (or 26.4V for 24V output model) for 5 seconds.

When the input voltage is above 11.8V 

(or 23.6V for 24V input model)

 for at least 5 seconds, the 

converter will automa cally jump to the "Charge mode". In this mode the converter supplies 
14.4V 

(or 28.8V for 24V output model)

 and both the yellow (input) and the green (output) LEDs 

are on.

The TDCi-CH will restart this charge process again when:

Opera on

Standby current

± 20mA

Opera ng temp.

-10° ... +40°C

Connec ons

6.3mm Faston

Dimensions

190x132x83mm

Weight

1.31kg

+

Wiring diagram

Ba ery or DC source

Input

+

+

DC/DC Charger

fuse

Input

Load / consumers

(connected in parallel 

with output ba ery)

Output

+

Output

fuse

Ba ery

Reviews: