5.3.3 Advanced Configuration
Only with password, you can enter into this setting.
Please consult with your battery manufacturer before you enter into this setting.
Wrong setting can permanently damage the battery.
It is critical to install the temperature sensor to perform right charging and
protection. If not installed, the equipment will assume 40
℃
.
Setting Page
Value
Default
Description
Charger constant voltage
14-15.2Vdc
default
Constant voltage timer
1-4hrs
2hrs
Charger floating voltage
13-13.8Vdc
default
Temperature Compensation rate
3-5mV
4mV
set the temperature
compensation rate. The
value is for per Cell/C
Charger Equalization voltage
15.0-16.5Vdc
default
Charger Equalization timer
30mins-2hrs
30mins
Changing the max time of
Equalization charging stage
Tab5-6 Advanced Battery Configuration
Notice
For above default setting, please refer to chapter 5.3.2 Default battery types and charging