1

USER INSTRUCTION  

TAZ LOV2

 2018.12.14

Follow on 

www.taz3d.fr   

for updates and additional information

LOV

2

Summary of Contents for LOV2

Page 1: ...1 USER INSTRUCTION TAZ LOV2 2018 12 14 Follow on www taz3d fr for updates and additional information LOV2...

Page 2: ...inox et deux rondelles inox Un ensemble taquet 12 permet la tenue de l EPI sur la corde au repos un taquet plastique un ressort de torsion et un axe inox Alloy stainless steel and plastics Fix plate...

Page 3: ...re la notice Produit fabriqu en France Marquage de rappel concernant la direction de mise en place de la corde Marquage de rappel concernant le point de connexion L gende des sch mas Ancrage EN 795 b...

Page 4: ...cle sur la trajectoire de la chute Les cordes doivent tre statiques EN 1891 type A de diam tre cit plus haut le harnais doit tre normalis EN 361 et les connecteurs EN 362 doivent tre verrouillage auto...

Page 5: ...ructions de TAZ COMPATIBILIT Un harnais antichute est le seul dispositif de pr hension du corps qu il soit permis d utiliser dans un syst me d arr t des chutes N utiliser comme connecteur au dispositi...

Page 6: ...de l autre main P 2 On obtient la vitesse voulue en jaugeant la traction sur la poign e et ou en freinant avec la main sur la partie basse de la corde en sortie du dispositif Ne pas d passer des vite...

Page 7: ...oute modification changement de pi ces r paration est interdite en dehors des ateliers de TAZ sauf pour le remplacement du taquet selon la proc dure TAZ STOCKAGE TRANSPORT PRODUITS Le dispositif ne do...

Page 8: ...the instructions Made in France Indication for the rope installation Indication for the connecting point Anchorage Schema indication EN 795 b 12KN Braked rope side CHECKING IF TOO MUCH PLAY LOOSENESS...

Page 9: ...manage the adequate technical competences and read the user instructions Activities at height require medical capacities They are dangerous and can cause serious injuries or death An emergency plan of...

Page 10: ...ed or not with a lanyard EN 354 max length 40 cm meaning it is still handling Check during use than connecters work in the good way of tension The ropes must be EN 1891 1998 class A de 10 11mm for a m...

Page 11: ...AUTION to forward the tool during descent use any suitable means which allows the harness connection to work in case No limit for number of descents or height of descent except in special cases of res...

Page 12: ...roduction control 0082 APAVE SUD EUROPE SAS BP 193 13322 MARSEILLE Cedex 16 FRANCE Conform to the directive 89_686_CEE CAUTION in case of retail abroad the destined country this user instruction as th...

Page 13: ...LL ARREST DESCENT MISE EN PLACE ET UTILISATION USING SET UP TAZ LOV2 Mod les rouge noir et noir EN 12841 2006 type A et C TAZ Ateliers relais EUREKALP ZA Tire Poix 38660 St Vincent de Mercuze www taz3...