INSTALLATION

 - RECEIVER MODULE

7

 

INSTALL RECEIVER MODULE

 

a.  Remove the battery cover (push it up and pull it out).

 

b.  Connect the IC wires and ensure the cylinder torque blade is engaged with the turn piece then 

 

  attach the interior assembly to the door with the metal screws.

 

c.  Insert 4 (AA) 1.5V alkaline batteries and place the cover back onto the interior assembly.  

BATTERY

COVER

METAL

SCREWS

WOOD

SCREWS

a.

b.

c.

Summary of Contents for CONCIERGE 100

Page 1: ...CONCIERGE 100 PROFESSIONAL SERIES ELECTRONIC DEADBOLT USER GUIDE ...

Page 2: ... INFORMATION 16 PROGRAMMING 1 AUTOMATIC BOLT DIRECTION ADJUSTMENT 17 2 CHANGE PROGRAMMING CODE 18 3 ADD DELETE USER ENTRY CODE 19 4 DELETE ALL USER ENTRY CODES AT ONCE 20 5 TEMPORARILY DISABLE ALL USER CODES 21 6 CREATE A DISPOSABLE USER ENTRY CODE 22 7 AUTO LOCK FUNCTION 23 8 MUTE ON OFF 24 9 RESTORE FACTORY SETTING 25 OPERATION 26 27 TROUBLESHOOTING GUIDE 28 29 INFORMATION PAGE 30 WARRANTY 31 CO...

Page 3: ...run the risk of voiding the limited warranty 2 Do not drop or hit the lockset 3 Do not use sharp objects to press key buttons 4 Always create a backup of information you want to keep such as programming code and use codes Please use the last page of this booklet as your reference 5 Please change programming code before operating this lockset CARE AND MAINTENANCE The following care instructions sho...

Page 4: ...HAMMER PHILLIPS SCREWDRIVER 1 25 mm 1 8 3 mm DRILL BITS 2 1 8 54 mm HOLE BORING KIT POWER DRILL 2 51 mm 6D COMMON NAIL 4 AA 1 5V ALKALINE BATTERIES TOOLS NEEDED FOR NEW INSTALLATION 2 REGISTERED TRADEMARK OF TAYMOR INDUSTRIES LTD ...

Page 5: ...STRIES LTD 3 COMPONENTS OF ELECTRONIC KEYPAD DEADBOLT INTERIOR BATTERY COVER WOOD SCREWS METAL SCREWS MOUNTING BOLTS MOUNTING PLATE INTERIOR ASSEMBLY WOOD SCREWS LATCH RUBBER GASKET CYLINDER TORQUE BLADE CYLINDER EXTERIOR ASSEMBLY IC WIRE ...

Page 6: ... PREPARATION 1 MARK DOOR WITH TEMPLATE ATTACHED SEPARATELY Note If replacing an existing lock or installing in a pre drilled door begin with page 8 a Use TEMPLATE to mark centerline on door for deadbolt about 3 to 6 75 mm to 150 mm above the existing knob or lever b Stand so door swings towards you Align template on centerline and fold template as shown ...

Page 7: ...T DRILL 1 8 3 mm PILOT HOLE 1 25 mm 2 1 8 54 mm DRILL 1 8 3 mm PILOT HOLE REGISTERED TRADEMARK OF TAYMOR INDUSTRIES LTD 5 DOOR PREPARATION 2 MARK AND DRILL PILOT HOLES Select backset Mark and drill pilot holes as shown ...

Page 8: ...door face from both sides to prevent wood from splitting b Drill a 1 25 mm hole in the door edge for the latch c Use the latch faceplate as a pattern for the mortise and pilot holes Chisel 1 8 3 mm deep Faceplate should fit flush Note for drive in latch simply insert latch a b c 2 1 8 54 mm 1 25 mm FACEPLATE OUTLINE CHISEL 1 8 3 mm DEEP ...

Page 9: ...rk horizontal centerline and outline of the strike Ensure the center of the faceplate and the center of the strike are aligned b Chisel 5 64 2 mm deep along the strike outline to allow the strike to be aligned with the door frame c Insert the strike and tighten it with wood screws Door jamb hole dimension a 1 3 16 30 mm b 1 3 8 35 mm c 1 25 mm Strike dimension d 9 32 7 mm e 2 15 16 75 mm f 1 5 16 ...

Page 10: ...aceplate form the backplate 2 Snap the selected faceplate onto the backplate Latch Backset Adjustment To rotate the latch case as following illustration for backset 2 3 4 70 mm or reverse direction for 2 3 8 60 mm Drive in Installation Make sure the round faceplate is properly aligned as illustrated and snap it to the latch case DRIVE IN LATCH 2 3 4 70 mm ...

Page 11: ...D AREA OR DRIVE IN LATCH If your door is set up to use a standard type latch please install it with the 3 4 20 mm screws that are provided If you use the drive in latch please tap it into place BACKSET FACEPLATE 3 4 20 mm WOOD SCREWS OR DRIVE IN LATCH TAP LATCH FLUSH WOOD BLOCK NOT INCLUDED ...

Page 12: ...ON 3 a Make sure latch is in retracted position b Insert the cylinder into exterior assembly with cylinder torque blade inserted through hub of the latch in a horizontal position c Pass the IC wire under the latch to the interior side of the door a b c IC WIRE ...

Page 13: ...sembly and cylinder are pressed flush against the exterior door insert the mounting bolts and tighten c Check the vertical alignment for the mounting plate and exterior assembly d Test Using the key retract and extend the bolt a few times to test for smooth action e If action feels rough loosen screws and realign the mounting plate and exterior assembly KEEP PARALLEL MOUNTING PLATE MOUNTING BOLTS ...

Page 14: ...handed if the hinges are on the left hand side of the door c The door is right handed if the hinges are on the right hand side of the door 6 ADJUST INTERIOR TURN PIECE a Turn the turn piece to the left when it is a right handed door b Turn the turn piece to the right when it is a left handed door LEFT HANDED RIGHT HANDED INTERIOR EXTERIOR HINGE DOOR ...

Page 15: ... cover push it up and pull it out b Connect the IC wires and ensure the cylinder torque blade is engaged with the turn piece then attach the interior assembly to the door with the metal screws c Insert 4 AA 1 5V alkaline batteries and place the cover back onto the interior assembly BATTERY COVER METAL SCREWS WOOD SCREWS a b c ...

Page 16: ...k Button 2 KEYPAD WITH NUMBER BUTTONS For inputting codes 4 10 digits in length 3 CYLINDER Retract Expand latch bolt by key from outside 4 RUBBER GASKET To prevent water leaking through exterior assembly 5 BATTERY COVER 6 BATTERY HUB Four AA Alkaline Batteries sold separately 7 R BUTTON RESET Restore default setting 8 TURN PIECE Retract Expand the latch bolt from inside 1 2 3 4 6 7 8 5 ...

Page 17: ...isabled for 45 seconds 5 Flashes Orange three times when system was restored to default setting 6 Flashes Orange slowly while in programming mode AUDIO WARNINGS 1 One Beep operating function was performed properly 2 Two Beeps programming function was performed properly 3 Three Beeps operating function was not performed properly LOW BATTERY WARNING LED indicator flashes Red and constant Beep sound ...

Page 18: ...programming code is 0 0 0 0 and can be changed anytime if needed USER ENTRY CODE 1 User entry code allows the individual user to lock and unlock the deadbolt 2 The factory preset user entry code is 1 2 3 4 Please delete it and create your personal unique user entry code as soon as the deadbolt is installed 3 User entry code can be 4 10 digits in length 4 Maximum of 6 user entry codes can be progra...

Page 19: ...t throw direction is automatically adjusted to left or right handed door 1 Deadbolt should be in unlocked position 2 Make sure the interior thumbturn position is identified properly according to door handing see page 12 FUNCTION STEPS Detect Left Right Hand Door Installation Enter Programming Code Press 0 ...

Page 20: ...hile in programming mode LED indicator flashes Green twice with 2 long Beeps when programming function is performed correctly LED indicator light flashes three times with three Beeps when programming function is performed incorrectly Note wait for at least 6 seconds or press and repeat programming steps if programming error was committed 3 Every programming step should be performed in 6 seconds or...

Page 21: ...e even if it was deleted before 2 The factory preset user entry code is 1 2 3 4 Please delete it and create your personal unique user entry code once the deadbolt is installed FUNCTION STEPS Add New User Entry Code Enter Programming Code Press 1 Enter New User Entry Code Delete Existing User Entry Code Enter Programming Code Press 2 Enter User Entry Code you want to delete ...

Page 22: ...me numbers as new codes even if they have been deleted before 2 Auto Lock and Keypad Lock functions will be invalid after deleting all user entry user entry codes and the deadbolt can only be operated by regular key The functions will be restored when the new user entry codes are created FUNCTION STEPS Delete all User Entry Codes at once Enter Programming Code Press 3 ...

Page 23: ... Lock and Keypad Lock functions will be invalid when all user entry codes are temporarily disabled The deadbolt can only be operated by regular key at this time 2 Repeat the programming steps to restore all user entry codes FUNCTION STEPS Disable Enable all User Entry Codes Enter Programming Code Press 8 ...

Page 24: ...REATE A DISPOSABLE USER ENTRY CODE 1 Disposable entry code can only be used once 2 You can reuse the same number as a disposable user entry code again FUNCTION STEPS Create Disposable User Entry Code Enter Programming Code Press 9 Enter New Disposable Entrly Code ...

Page 25: ...the factory 3 Auto Lock time delay is preset to 30 seconds It can be adjusted to 10 to 99 seconds if needed 4 The system will signal an operating error if the deadbolt fails to latch properly Re enter valid user entry code to unlock the door and retract the latchbolt Auto Lock function is now restored FUNCTION STEPS Auto Lock ON OFF Enter Programming Code Press 5 Auto Lock Time Delay Enter Program...

Page 26: ...FF 1 Audible Beep alerts when pressing keypad buttons during programming or operating errors can be turned off if needed 2 LED indicator light will still function when muted 3 Motor operating sound cannot be muted FUNCTION STEPS Mute ON OFF Enter Programming Code Press 7 ...

Page 27: ...cate R button 2 Press R button for at least 5 seconds until you hear three long Beeps 3 The deadbolt is now reset back to the factory setting programming code 0 0 0 0 user entry code 1 2 3 4 4 Repeat automatic bolt direction adjustment see page 17 before you proceed to programming any other functin into the deadbolt ...

Page 28: ...Press or use regular key to lock the deadbolt from outside 2 Turn thumbturn piece to lock the deadbolt from inside TO UNLOCK 1 Enter valid user entry code and press or use regular key to unlock the deadbolt from the outside 2 Turn thumbturn piece to unlock the deadbolt from the inside ...

Page 29: ...TAYMOR INDUSTRIES LTD 27 OPERATION SECURITY MODE 1 The keypad will be automatically deactivated for 45 seconds after 5 unauthorized entry attempts 2 The deadbolt can be locked and unlocked by the regular key under security mode ...

Page 30: ...h hub in a horizontal position 3 Repeat the Automatic Bolt Direction routine see page 17 B Sometimes when I operate the lock manually I feel a bump while turning the thumbturn or key 1 The electromechanical components of the lockset are out of sync To re synchronize the system please lock and then unlock the deadbolt using the keypad C In am pressing any button on the keypad and it doesn t seem to...

Page 31: ... sure that every programming step is completed in under 6 seconds B What type of batteries do you recommend 1 For best results please use new non rechargeable alkaline batter ies 4 AA 1 5V C How long will the lock operate on one set of batteries 1 Based on 15 operations per day a single set of alkaline batteries will operate the lockset for over a year ...

Page 32: ...ANT NOTE 1 Do not share your programming code with anyone else 2 Keep a written copy of all valid user codes in a safe place You may use the table below to record your information 3 You are advised to re program all codes if you lost any security information in the table PROGRAMMING CODE ...

Page 33: ...long as the original owner owns his her home Taymor will replace free of charge during the warranty period any part that fails to meet the warranty under normal installation and use as long as the product has been cared for according to the care instructions listed in the package and on the website Electronic components of this lock are limited to 1 one year from the date of purchase For more deta...

Reviews: