6-6
OPERATING PROCEDURES
Models RD30/RC25
Operating Procedures
6
3. If the sanitizing solution does not continue to flow
after releasing the prime button, press and hold the
prime button for an additional 10 seconds. Repeat
this procedure as required to prime the post mix
valve.
Figure 6-25
4. Drain the sanitizing solution from the freezing
cylinder and repeat this procedure until all the
sanitizing solution is dispensed from the mix delivery
container. Disconnect the mix delivery container.
Figure 6-26
Important!
The machine must
not
be placed in Auto
mode until all sanitizing solution has been removed
from the freezing cylinder and proper priming
procedures have been completed. Failure to follow
this instruction may result in damage to the freezing
cylinder.
Dispenser
1. Prepare a pail of approved 100 ppm sanitizing
solution (examples: 2-1/2 gal. [9.5 L] of Kay-5
®
or 2
gal. [7.6 L] of Stera-Sheen
®
). Use warm water and
follow the manufacturer’s specifications. Remove the
upper rear cover, and open the hopper cover. Pour
the sanitizing solution into the hopper and allow the
solution to flow into the freezing cylinder.
Figure 6-27
2. Once the mix float switch is submerged in the
sanitizing solution, brush-clean the mix hopper, mix
inlet hole, and mix-level float switch.
Figure 6-28
Summary of Contents for RD30
Page 16: ...5 2 USER INTERFACE Models RD30 RC25 User Interface 5 Notes...
Page 26: ...6 10 OPERATING PROCEDURES Models RD30 RC25 Operating Procedures 6 Notes...
Page 32: ...9 2 PARTS REPLACEMENT SCHEDULE Models RD30 RC25 Parts Replacement Schedule 9 Notes...
Page 38: ...11 4 LIMITED WARRANTY ON PARTS Models RD30 RC25 Limited Warranty on Parts 11 Notes...