61
Model R280
Ordering/Service Information
Taylor distributor:__________________________
Address:_________________________________
Phone:__________________________________
Date of installation:________________________
Data Label
The data label provides necessary information that the
operator should record and refer to when calling for parts
or service. The data label is located on the rear or left
side panel of the freezer.
Complete for quick reference when this information is
requested.
1. Model Number: R280
2. Serial Number_________________________
3. Electrical Specs:
Voltage______ Cycle______ Phase______
4. Maximum Fuse Size: _________Amps
5. Minimum Wire Ampacity:_______Amps
6. Part Number:__________________________
Parts Warranty
See the Limited Warranty on Parts section starting on
page 58.
Note:
Constant research results in steady
improvements; therefore, information in this manual is
subject to change without notice.
Compressor Warranty Disclaimer
The refrigeration compressor(s) on this unit are
warranted for the term stated in the Limited Warranty
section in this manual. However, due to the Montreal
Protocol and the U.S. Clean Air Act Amendments of
1990, many new refrigerants are being tested and
developed, thus seeking their way into the service
industry. Some of these new refrigerants are being
advertised as drop-in replacements for numerous
applications. It should be noted that in the event of
ordinary service to this unit's refrigeration system,
only
the refrigerant specified on the affixed data label
should be used.
The unauthorized use of alternate
refrigerants will void your Taylor compressor warranty. It
is the unit owner's responsibility to make this fact known
to any technician he/she employs.
It should also be noted that Taylor does not warrant the
refrigerant used in its equipment. For example, if the
refrigerant is lost during the course of ordinary service to
this unit, Taylor has no obligation to either supply or
provide replacement refrigerant either at billable or
unbillable terms. Taylor will recommend a suitable
replacement if the original refrigerant is banned,
obsoleted, or no longer available during the five-year
Taylor warranty of the compressor.
From time-to-time Taylor may test new refrigerant
alternates. Should a new refrigerant alternate prove,
through Taylor's testing, that it would be accepted as a
drop-in replacement for this unit, then the disclaimer in
this “Compressor Warranty Disclaimer” section will not
apply to the use of the alternate refrigerant approved by
Taylor.
To find out the current status of an alternate refrigerant as
it relates to your compressor warranty, call Taylor or your
local authorized Taylor distributor. Be prepared to provide
the model/serial number of the machine in question.
Note:
Continuing research results in steady
improvements; therefore, information in this Operator’s
Manual is subject to change without notice.