20
ERROR DETECTION
The main display will read **Error** and state the error which has occurred (e.g. Weighing Issue).
If an error does occur, it is normally reset by pushing the OK button. If the failure continues, turn the power switch off
and unplug the power cord from the wall outlet. Check the power cord for any obvious defect. Open the cabinet door to
make sure the Dispenser is properly assembled (page 6) and the product is loaded properly.
See page 21 for troubleshooting an error condition.
Error Codes
Error
Description
Drum Won’t Turn
Drum motor is not turning. (Error 1)
Fry Doors Stuck
Accumulator motor is not turning. (Error 2)
Fry Door Failed
Timeout error on accumulator. (Error 3)
Weighing Issue
Tare weight has shifted excessively. (Error 4)
Cooling Slow
Refrigeration progress too slow. (Error 5)
Cooling Failed
Refrigeration high-pressure switch may have tripped. (Error 6)
Refrig. Error
Error on refrigeration relay drive. (Error 7)
Probe Failure
Temperature probe input out of range. (Error 8)
DC Power Low
DC voltage low
NV Data Lost
Invalid data in Configuration (normal at first start-up)
NV Data Bad
Call factory.
Internal Issue
Call factory.
Summary of Contents for McDonald's R200
Page 50: ...48 ELECTRICAL DIAGRAM Figure 33 ...