27
Models 8752, 8756, 8757
Operating Procedures
140306
Note:
Alignment of the air/mix pump is extremely
important. Severe and costly damage may occur if it is
not properly aligned.
Step 9
Lubricate both sides of the pressure switch
diaphragm.
Figure 38
Step 10
Place the diaphragm on the front face of the pressure
switch housing. The lubricant will act as an adhesive
to hold the diaphragm in place.
Note: DO NOT
place the diaphragm in the pressure
switch cap.
Step 11
Screw the cap onto the housing securely.
Figure 39
Repeat Steps 1 through 8
for the other side of the
freezer on the Models 8756 and 8757.