6-8
OPERATING PROCEDURES
Model C302
Operating Procedures
6
4. Place the sampling valve in the OFF (center)
position.
Figure 6-29
5. Press the PRIME (+ + +) key.
Figure 6-30
6. Slowly move the syrup sampling valve to the fully
open position by turning the handle down toward the
sampling line. Allow the liquid to run into a pail until
all the sanitizer is removed and full-strength product
is flowing.
Figure 6-31
Brix is the ratio of syrup to water which will directly affect
the quality and taste of the product. Brixing should be
done before priming the freezer and when a change in
syrup flavor has been made.
7. Pour the product from the syrup sampling valve into a
cup. Close the syrup sampling valve by turning the
handle to the center position.
Figure 6-32
8. Stir the finished product. Pour a small amount of
product over the refractometer. The brix reading
should register 13 to 14. A reading higher than this
would cause a darker, richer product. The
refrigeration system would have to run longer to
freeze this excess syrup. A reading lower than this
could cause a freeze-up in the freezing cylinder
because of the excess water.
Figure 6-33
18092
13039p
18032
18092
17026
Summary of Contents for C302
Page 10: ...2 2 TO THE OPERATOR Model C302 To the Operator 2 Notes...
Page 14: ...3 4 SAFETY Model C302 Safety 3 Notes...
Page 40: ...7 2 OPERATOR CHECKLIST Model C302 Operator Checklist 7 Notes...
Page 44: ...9 2 PARTS REPLACEMENT SCHEDULE Model C302 Parts Replacement Schedule 9 Notes...
Page 48: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C302 Limited Warranty on Equipment 10 Notes...
Page 52: ...11 4 LIMITED WARRANTY ON PARTS Model C302 Limited Warranty on Parts 11 Notes...