![Taylor-Dunn G0-010-00 Service And Replacement Parts Manual Download Page 361](http://html1.mh-extra.com/html/taylor-dunn/g0-010-00/g0-010-00_service-and-replacement-parts-manual_3839738361.webp)
9929758 R01 - 2019 TAYLOR-DUNN G-100 Service Manual
© Copyright TAYLOR-DUNN
11.29
STARTER SOLENOID BENCH TEST
Test the start solenoid by powering the solenoid using
battery voltage for a
maximum of 5 seconds
. With the
solenoid energized, there should be continuity between
terminals (A) and (B). If there is no continuity or high
resistance, replace the starter solenoid.
STARTER SOLENOID OPERATION
To energize the starter solenoid the following must occur:
• The brake must be applied to provide a ground path
via the Brown / Yellow wire.
• The key switch must be turned to the “start” position to
provide 12V power via the White / Red wire.
• Once the pull-in coil is energized, the solenoid
provides a current path for 12V power to reach the
starter motor.
Summary of Contents for G0-010-00
Page 60: ...2 36 9929758 R01 2019 TAYLOR DUNN G 100 Service Manual Copyright TAYLOR DUNN NOTES MAINTENANCE...
Page 196: ...4 48 9929758 R01 2019 TAYLOR DUNN G 100 Service Manual Copyright TAYLOR DUNN NOTES FUEL SYSTEM...
Page 224: ...5 28 9929758 R01 2019 TAYLOR DUNN G 100 Service Manual Copyright TAYLOR DUNN NOTES CVT SYSTEM...