Page 39
B-210 / B-200 Curtis System Operator Manual
MB-210-14
Code
CAUSE
SOLUTION
1
High battery voltage
Check battery size and condition.
Fault will clear automatically once the
condition has been corrected.
2
Low battery voltage
Check battery size and condition.
Fault will clear automatically once the
condition has been corrected.
3
Charge time out
caused by battery
pack not reaching
r e q u i r e d v o l t a g e
or charger output
reduced due to high
temperatures.
Check battery connections.
Confirm that the battery type matches
selected charge profile
Operate the charger at a lower ambient
temperature.
Reset the charger by interrupting AC
power for 15+ seconds.
4
Battery could not be
trickle charged up
to minimum voltage.
Check for shorted or damaged cells.
Reset the charger by interrupting power
for 15+ seconds.
5
Charger shutdown
due to high internal
temperature.
Ensure sufficient cooling airflow.
Reset the charger by interrupting AC
power for 15+ seconds.
6
Internal charger fault
Reset the charger by interrupting
AC power for 15+ seconds. Refer to
qualified technician if fault persists.
Lester Summit Charger
Description of Operation
The Summit charger is designed as an automatic charger. It is available with charging profiles
for SLA and FLA batteries. Refer to the spec plate on the charger for the type of battery it is
configured for. Use of different batteries not listed on the spec plate may result in premature
failure of the batteries.
The charger turns itself on when it is plugged into the wall outlet and turns off when the batteries
are fully charged. The charger continues to monitor the battery voltage and if the battery voltage
drops below a threshold value, then the charger will turn on again for a short cycle to keep the
batteries topped off.
There are three lamps on the charger used to indicate
the active charging status and if any faults occurred
during the charging cycle.
Status Lamps