
Taurus Super-S LCM LCD Display
3.4.5 Fan Speed Setup
For the smart-fan to automatically regulate the fan speed according to the internal temperature, the
thermal probe has to be installed.
[Automatic] Regulates the fan speed according to the internal temperature (below 40˚C = low
speed, 40-50˚C = medium speed, above 50˚C = high speed).
[HighSpeed] Fan speed is set to high speed.
[LowSpeed] Fan speed is set to low speed.
[OFF] The fan is turned off. This setting should only be used if the device is located in a cool
and temperature controlled room.
Press the [OK] button to enter the setup menu and press the [Select] button to cycle through the
different options.
To exit the menu without changing any of the settings, press the [Select] button until you see
the Exit screen and then press the [OK] button.
To change the setting, press the [Select] button to choose your preferred mode and then press
the [OK] button to confirm the change.
Page 12