Thank you for purchasing Video Panel 4096, Every unit has been

thoroughly tested and has been shipped in perfect operating condition.

Carefully check the shipping carton for damage that may have occurred

during shipping. If the carton appears to be damaged, carefully inspect

your fixture for any damage and be sure all accessories necessary to

operate the unit has arrived intact. In the case damage has been found

or parts are missing, please contact the manufacturer or your dealer for

further instructions. You now own a professional lighting unit that offers

endless possibilities.

For your own safety and that of others, please read this instruction

manual carefully before installing the unit.

Anyone involved in installing, operating or servicing the Video Panel

4096 must:

Be a qualified, authorized professional

S

trictly follow the instructions in this user manual.

Please take the time to read this manual carefully and thoroughly before

installing and operating the luminaire. You should have a good

knowledge of its operating conditions and all pertinent product

information.

After you have become familiar with this manual, we recommend that

you keep a copy for future use. All the information found in this manual

Summary of Contents for Glamor Video Panel 4096

Page 1: ...1 Video Panel 4096 User Manual Thanks for choosing our goods please read this manual carefully before your operating and keep this manual for future needs ...

Page 2: ... You now own a professional lighting unit that offers endless possibilities For your own safety and that of others please read this instruction manual carefully before installing the unit Anyone involved in installing operating or servicing the Video Panel 4096 must Be a qualified authorized professional Strictly follow the instructions in this user manual Please take the time to read this manual ...

Page 3: ...to the device are not subject to warranty Installation The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating And make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12...

Page 4: ...ngnet Graphic LCD display for addressing and special functions settings with flip function Over temperature protection Moving head skeleton made of aluminium and steel metal plates Pixels Density 16384dots m2 View Angle H145 V110 Video Output DVI DMX Powercon In Out 3pin 5pin XLR in and out Ethercon RJ45 IN OUT connectors Power Input AC110 to 240 Volts 50 60Hz Power 180W Max Size 473 x 641 x 307 m...

Page 5: ...5 Product View Menu Operation DMX When DMX Signal in the LED will be flash ERR When the Light error the LED will be flash Mode ESC ENTER Left button Right button Up button Down button ...

Page 6: ...6 ...

Page 7: ...movement 236 255 No function 6 4 Pan Motor continuous rotation 0 127 no function 128 189 Forwards Pan rotation from fast to slow 190 193 No rotation 194 255 Backwards Pan rotation from slow to fast 7 5 Tilt Motor continuous rotation 0 127 No function 128 189 Forwards Tilt rotation from fast to slow 190 193 No rotation 194 255 Backwards Tilt rotation from slow to fast 8 6 Red LED 0 255 Red 0 Black ...

Page 8: ...GREEN 72 103 From GREEN to CYAN 104 135 From CYAN to BLUE 136 167 from BLUE to MAGENTA 168 199 from MAGENTA to RED 200 231 from RED to WHITE 232 255 Cross fading colours from slow to fast 15 13 Color Presets 0 4 No function 5 9 White2700k 10 14 White3200k 15 19 White4300k 20 24 White5600k 25 29 White6500k 30 34 White8000k 35 39 Yellow 40 44 Magenta 45 49 Cyan 50 54 Salmon 55 59 Turquoise 60 64 Lig...

Page 9: ...a DMX LED should be on If not check DMX connectors cables to see if link properly b If the DMX LED is on and no response to the channel check the address settings and DMX polarity c If you have intermittent DMX signal problems check the pins on 16 14 Color Presets Dimmer 0 255 Dimmer 100 to 0 17 15 Reset internal Auto 0 79 Normal 80 84 All motor reset 85 99 No function 100 119 Internal Auto1 120 1...

Page 10: ...t the proper address 4 One of the channels is not working well a The stepper motor might be damaged or the cable connected to the PCB is broken b The motor s drive IC on the PCB might be out of condition 5 Fixture Cleaning The cleaning of intermal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in wh...

Page 11: ...cosmetic defects caused by the normal wear and tear of the unit are not covered under the warranty Any modification to the fixture will void the warranty We cannot under any circumstances be held liable for quality and conformity regarding the installation of this product which is the responsibility of the installer the device and before use may be covered by the warranty The manufacturer is not r...