background image

User Installation Manual 

 

SmartAire

®

 MZ Basic

 

 

  

7510 Montevideo Road 

r1.0-12/11/15

     

 

 

© 2015 Tate Access Floors, Inc.  

Jessup, MD 20794 

SmartAire_mzb_Installation.docx 

 

Tel (410)799-4200 

 

1 of 27 

 

 

 

SmartAire

®

 MZ Basic 

 

User Installation Guide 

 

 

Please Read and Save 

These Instructions 

Summary of Contents for SmartAire MZ Basic

Page 1: ...ire MZ Basic 7510 Montevideo Road r1 0 12 11 15 2015 Tate Access Floors Inc Jessup MD 20794 SmartAire_mzb_Installation docx Tel 410 799 4200 1 of 27 SmartAire MZ Basic User Installation Guide Please R...

Page 2: ...dicator to the Rack Face 8 Step 4 Connect the Sensor to the Tree 9 Step 5 Connect the LED Indicator 9 Step 6 Connect the Tree to the SmartAire MZ 10 Step 7 Turn the Battery On 11 Step 8 Connect the Po...

Page 3: ...the installation is complete All work conducted on units should only be conducted by a trained professional Modifying equipment other than in ways suggested and approved by Tate are not recommended or...

Page 4: ...uv s par Tate sont ni recommand ni support et peut endommager l quipement ou causer un pr judice Il est recommand que la batterie est test chaque ann e pour assurer le bon fonctionnement et l exploita...

Page 5: ...IEEE 802 3af compliant x1 Property IEEE 802 3af Power available at PD 12 95 W Maximum power delivered by PSE 15 40 W Voltage range at PSE 44 0 57 0 V Voltage range at PD 37 0 57 0 V Maximum current 3...

Page 6: ...sic 7510 Montevideo Road r1 0 12 11 15 2015 Tate Access Floors Inc Jessup MD 20794 SmartAire_mzb_Installation docx Tel 410 799 4200 6 of 27 QUICK INSTALLATION ALUMINUM DIRECTAIRE CABINET FACE QUICK IN...

Page 7: ...uctions Unpack unit and all accessories Prepare zip ties and associated mounting hardware available nearby Prepare the DirectAire or DirectAire Al Panel and Installation Location HANDLE UNIT WITH CARE...

Page 8: ...sensors to the face of the rack STEP 3 ATTACH THE SENSOR LED INDICATOR TO THE RACK FACE Mount the temperature sensor to the face of the rack Zip ties can be used to assist in mounting the sensor The...

Page 9: ...Installation docx Tel 410 799 4200 9 of 27 STEP 4 CONNECT THE SENSOR TO THE TREE Connect temperature sensor 1 to the temperature tree Split Connector RGB LED Indicator and Sensor 1 Note that SmartAire...

Page 10: ...TEP 6 CONNECT THE TREE TO THE SMARTAIRE MZ Though the hole in the floor where the SmartAire is to be installed Connect the temperature tree into the SENSOR PORT The Sensor will only connect in one ori...

Page 11: ...up MD 20794 SmartAire_mzb_Installation docx Tel 410 799 4200 11 of 27 STEP 7 TURN THE BATTERY ON Switch the Battery backup to the ON Position IT IS NECESSARY TO HAVE THE BATTERY IN THE ON POSITION DUR...

Page 12: ...ould be suggested as the preferred option for powering the SmartAire Unit For redundant installation both the PoE and DC Coaxial supply can be provided but this is not necessary Once power is supplied...

Page 13: ...extended position Then Retighten the screws down to lock them in position A MANUAL PHILIPS HEAD SCREWDRIVER OR A TORQUE LIMITING ELECTRIC SCREW DRIVER IS BEST FOR THIS PORTION OF THE INSTALLATION TO A...

Page 14: ...e DirectAire Al The display should be mounted in the orientation that it fits on the edge meant to go Towards the rack it is cooling Hand Screw in the four 5mmx 5mm Screws Confirm SmartAire MZ is moun...

Page 15: ...stringer bases to the left and right parallel stringers to the face of the rack Safely lower the fully extended SmartAire onto the stringer hangers you may need to slightly tilt the hangers inward to...

Page 16: ...re panel directly on top of the preinstalled SmartAire MZ on hangers The DirectAire should rest just above the SmartAire and not apply any force to the SmartAire If this is not the case please contact...

Page 17: ...dampers CHANGING MODES 3 Mode This button is disabled on the SmartAire Basic Basic Mode Basic Mode is designed to only allow the SmartAire to operate as an adjustable damper Once placed into basic mod...

Page 18: ...panel described in the following section TCP IP ADVANCED PROGRAMMING MONITORING 1 The advanced programming and monitoring menu should only be accessed by someone who is knowledgeable 2 New and unteste...

Page 19: ...1 or more SMARTAIREMZ should appear within the window each with a specific IP and MAC Address Each line represents one SmartAire unit Note that SmartAire MZ requires connection to a dynamic DHCP netw...

Page 20: ...s from SmartAire MZ must have access non firewalled access to Smtp Gmail com and port 465 to function properly d Network Configuration Interface to configure Network connectivity System can be configu...

Page 21: ...inimum Possible Value 0 0 100 T3_Min Override Minimum Possible Value 0 0 100 T4_Min Override Minimum Possible Value 0 0 100 T1_Max Override Maximum Possible Value 100 0 100 T2_Max Override Maximum Pos...

Page 22: ...y disabling zones on the SmartAire Zone 2 Disable Enable 0 Disable 1 Enable 1 0 1 Zone 3 Disable Enable 0 Disable 1 Enable 1 0 1 Zone 4 Disable Enable 0 Disable 1 Enable 1 0 1 LED_Hi High Temperature...

Page 23: ...lue 0 1 3 6 1 2 1 1 5 0 OctetString SmartAire sysLocation 0 1 3 6 1 2 1 1 6 0 OctetString office sysServices 0 1 3 6 1 2 1 1 7 0 Integer 7 trapReceiverNumber 0 1 3 6 1 4 1 43431 1 2 1 1 1 0 Integer 0...

Page 24: ...tetString 81 RW_LEDHiWarn 0 1 3 6 1 4 1 43431 1 3 25 0 OctetString 79 RW_LEDLoWarn 0 1 3 6 1 4 1 43431 1 3 26 0 OctetString 73 RW_LEDLo 0 1 3 6 1 4 1 43431 1 3 27 0 OctetString 71 RW_LEDMode 0 1 3 6 1...

Page 25: ...IC UPGRADE To upgrade the SmartAire MZ Basic to the full version an upgrade kit must be purchased through Tate The upgrade kit consists of Sensors Labeled 2 3 and 4 To complete the upgrade process con...

Page 26: ...actory default reset cycle This will reset all parameters SNMP settings and TCP IP configurations and restore the unit to its default settings The unit will reboot after a 5 second delay upon completi...

Page 27: ...old the power button down until the unit powers down and then wait 10 seconds then press the power button again Contact Tate if the led still does not relight Warranty Refer to http tateinc com or con...