Cleaning the recovery tank

t

Switch on the vacuum motor only now.

The indicators light up.
The soiled water is now pressed out of the recovery tank.

t

Switch off the vacuum unit as soon the tank is empty.

Caution:

Now pull back the lever into the work position (page 5).

t

Turn off the machine (main switch).

t

Empty the recovery tank (Page 17).

t

Open the machine hood.

t

Remove the tank cover closing.

t

Take off the tank cover/dosing cup.

t

Remove the of the maintenance opening lid (page 5).

t

Clean the recovery tank thoroughly.

Caution:

Danger of injury due to sharp objects

Wear cloves to protect your hands from injurys!

Summary of Contents for combimat 1400

Page 1: ...800 ATTENTION Do not use the machine before you have read and understood the instructions of use Keep the instructions of use carefully in an easily accessible place so that they can be referred to at...

Page 2: ...Disposal 40 Index 41 EU Declaration of Conformity 42 Symbols Intended use of machinery The scrubber dryer is used to clean hard floor surfaces according to these instructions of use The machine is su...

Page 3: ...levant security and safety regulations While operating the machine take note of the surrounding area and pay particular attention to third parties and children Only use tools brushes pad drives which...

Page 4: ...might negatively affect the health of the user and third parties This machine is not suitable for outside use Should foam or liquid leak from the machine follow the instructions below Check that the l...

Page 5: ...lution tank opening maintenance 4 Squeegee lowering device 5 Squeegee 6 Squeegee adjustment 7 Squeegee pressure adjustment 8 Lever for reversing the air flow only co 15 1700 9 Brush unit 10 Machine ho...

Page 6: ...2 button only co 15 1700 19 Emergency stop button option co 1400 1600 1800 20 Brush pressure level 1 button only co 1500 1700 21 Recycling programm button option co 14 16 1800 22 Solution dosing contr...

Page 7: ...counter 29 Charge state display ready green 30 Charge state display unloaded red 31 Option Battery vacantness display 32 Solution tank 33 Recovery tank 34 Recycling filter 2 piece inside tank 35 Leve...

Page 8: ...500 1700 38 Fuses co 1400 1600 1800 39 Battery plug socket 40 Tools brush pad drive etc 39 F5 F5 F6 F6 F4 F4 F3 F3 F2 F2 F1 F1 F5 F5 F7 F8 F7 F8 F6 F6 F4 F4 F3 F3 F2 F2 F1 F1 37 co 1500 1700 38 co 140...

Page 9: ...it for at least 24 hours in order to ensure that you can use the batteries full capacity Charging batteries see page 30 t Switch off charger Caution Please read the instruction of use of the battery...

Page 10: ...g the speed control go stops the machine t Turn off the machine main switch t Open the machine hood This symbol indicates the solution tank t Remove the tank cover closing t Open the tank cover dosing...

Page 11: ...tank cover dosing cup in the solution tank t Close the tank with the tank cover and lock it t Close the machine hood t Turn off the machine main switch t Lift the squeegee lever with the foot t Loosen...

Page 12: ...rotect your hands from injurys t To lift the brush unit press the button t or t To lift the brush unit press the brush lever down turn it to the right and push it up until the end of the guide than tu...

Page 13: ...ndicators light up t Press down the squeegee lowering device t Press the vacuum button The indicators light up t Press the solution button The indicators light up t Choose the amount of solution min m...

Page 14: ...rn and the solution is fed through the middle of the tool If the battery control is blinking stop cleaning and drive back to the battery charger Caution The recycling system is not to use in areas wit...

Page 15: ...ner or representative Refilling the solution tank When the tools are no longer sufficiently fed by the solution the tank containing the solution is empty End of operation After cleaning Caution Do not...

Page 16: ...t up until the end of the guide than turn it left to snap in t Drive on a few metres further in order to pick up the remaining waste water t Lift the squeegee lever with the foot t Only now switch off...

Page 17: ...ff its fittings t Unscrew red cap Open the cap at the height of the handle and lower the hose end slowly to pour out the soiled solution t Conduct the emptying hose to a drain sink or a bucket t Empty...

Page 18: ...Caution Now pull back the lever into the work position page 5 t Turn off the machine main switch t Empty the recovery tank Page 17 t Open the machine hood t Remove the tank cover closing t Take off th...

Page 19: ...t Once the tank is empty put back the red cap and refix the hose to its fittings t Turn off the machine main switch t Remove the tank cover closing t Take off the tank cover dosing cup t Take off the...

Page 20: ...tank Page 19 t Remove the of the maintenance opening lid page 5 t Open the tank cover dosing cup t Take off the solution filter after each cleaning operation t Rinse the filter under running water If...

Page 21: ...ecovery tank Page 17 t Remove the tank cover closing t Take off the tank cover dosing cup t Remove the recycling filter of the recovery tank t Rinse the recycling standpipe of the filter thoroughly Ca...

Page 22: ...ift the brush unit press the brush lever down turn it to the right and push it up until the end of the guide than turn it left to snap in t Turn off the machine main switch Caution Danger of injury du...

Page 23: ...suction hose t Loosen the fixation knobs on the squeegee t Disassemble the squeegee t Clean the squeegee under running water with a brush Caution Danger of injury due to sharp objects Wear cloves to p...

Page 24: ...chine main switch t Wipe down the machine with a moist cloth Caution Never clean the machine with a high water pressure or a water hose The ingress of water into the machine might cause considerable d...

Page 25: ...your machine On the last page of these instructions of use you can find the address of your nearest TASKI partner Maintenance Repairs to mechanical or electrical parts of the machine must only be und...

Page 26: ...ng recycling machine 21 Check the solution filter and clean or descale it if necessary 20 Empty solution tank and rinse with fresh water 19 Cleaning tools brush pad drive etc 22 Clean squeegee check w...

Page 27: ...f the squeegee Insufficient suction result on the middle part of the squeegee t Turn off the machine main switch t Loose the hexagon bolt 6 mm spanner of the squeegee adjustment t Adjust the squeegee...

Page 28: ...ieved please see the following description Replace fuses t Turn off the machine main switch t Adjust according to the drawing on the right side t Adjust according to the drawing on the right side t Tu...

Page 29: ...disc and securely screw in the fuse t Then replace the cover on the holder F1 F4 Fuse ratings co 1400 1500 1600 1700 1800 F1 80A Main fuse F2 30A Drive motor F3 30A Brush motor F4 30A Vacuum motor t P...

Page 30: ...kdown on the brush lowering F8 Fuse ratings co 1400 1500 1600 1700 1800 F8 Safety automation Brush lowering only co 1500 1700 t Check whether the machine is turned off by turning of ignition key t Ope...

Page 31: ...d LED flashes the machine can be used for another minutes only Safety measures when working with batteries Never come near the batterie with open flames or glowing objects since this could cause an ex...

Page 32: ...es are discharged when the acidity is reduced to approx 18 B t Please enlist the measurements into the booklet t Please check the electrolyte and if needed fill it with distilled or desalinated water...

Page 33: ...tery 30 Machine dos not move Immobiliser is activated t Bring speed control to neutral position 5 Batteries not or not sufficiently charged Charger or connecting cable defective t Call for technical s...

Page 34: ...d replace if necessary t If the fuse is not defective call for technical service On the last page of these instructions of use 28 Tank cover dosing cup does not seal properly t Check seal and position...

Page 35: ...n filter blocked t Clean the cleaning solution filter 20 Deficiency in quantity chosen t Choose the volume of solution with the control knob min max 1 6 6 Solution dosing control switched off t Soluti...

Page 36: ...151 396 155 430 kg Rated voltage 24V 24V 24V dc Tools 2 x 280 2 x 280 2 x 350 mm Brush rpm 197 195 152 min 1 Brush pressure 34 31 43 42 kg Dimensions L x W x H 141 x 59 141 x 59 156 x 77 x 100 mm Rate...

Page 37: ...on max 155 430 157 480 kg Rated voltage 24V 24V dc Tools 2 x 350 2 x 430 mm Brush rpm 150 133 min 1 Brush pressure 42 61 60 kg Dimensions L x W x H 156 x 77 169 x 90 x 100 mm Rated power 1500 1700 W S...

Page 38: ...cm nylon X X Scrubbing brush abrasive 35cm X X Driving disc Instalok 35cm X X Scrubbing brush for washed concret 43cm X Scrubbing brush 43cm nylon X Scrubbing brush abrasive 43cm X Driving disc Instal...

Page 39: ...s The concentration is product dependent Caution Using other chemicals e g chemicals containing solvents chlorine hydrochloric acid and hydrofluoric acid can damage or destroy the machine Instructions...

Page 40: ...machine and its accessories must be disposed of according to the national regulations Your TASKI partner can support you with proper disposal upon notification Batteries The batteries must be removed...

Page 41: ...ght adjustment for handle height 5 Hours counter 7 I Index 41 Indicator main switch 6 Indirect working method 15 Insufficient suction result 27 Intended use of machinery 2 L Level probe 7 Lever brush...

Page 42: ...plied EN 60 335 1 94 EN 60 335 1 A1 96 EN 60 335 1 A2 00 EN 60 335 1 A11 95 EN 60 335 1 A12 96 EN 60 335 1 A13 98 EN 60 335 1 A14 98 EN 60 335 1 A15 00 EN 60 335 1 A16 01 EN 60 335 2 72 98 EN 60 335 2...

Page 43: ...9 11 avenue du Val de Fontenay 94133 Fontenay sous Bois C dex Tel 33 1 45 14 76 76 Fax 33 1 45 14 77 99 GB JohnsonDiversey Weston Favell Centre NN3 8PD Northampton Tel 44 1604 405 311 M 44 796 76 94 3...

Page 44: ...22 Moscow Tel 7 095 970 17 97 Fax 7 095 970 17 98 SE JohnsonDiversey AB Liljeholmsv gen 18 Box 47313 10074 Stockholm Tel 46 877 99 300 Fax 46 877 99 399 SI JohnsonDiversey d o o Trzaska cesta 37a 2000...

Reviews: