Task Force Tips Ultimatic Instructions For Installation, Operation And Maintenance Download Page 1

©Copyright Task Force Tips LLC 2012-2021

1

LIB-065 February 22, 2021 Rev02

TASK FORCE TIPS LLC

MADE IN USA · tft.com 

3701 Innovation Way, Valparaiso, IN 46383-9327 USA

800-348-2686 · 219-462-6161 · Fax 219-464-7155

INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION, AND MAINTENANCE

INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

 

Ultimatic

®

 ER Nozzles 

WARNING

Understand  manual  before  use.  Operation  of  this  device  without  understanding  the  manual  and

receiving proper training is a misuse of this equipment. Obtain safety information at tft.com/serial-

number. 
This equipment is intended for use by trained and qualified emergency services personnel for

firefighting. All personnel using this equipment shall have completed a course of education

approved by the Authority Having Jurisdiction (AHJ).
This instruction manual is intended to familiarize firefighters and maintenance personnel with the

operation, servicing, and safety procedures associated with this product. This manual should be

kept available to all operating and maintenance personnel. 

Summary of Contents for Ultimatic

Page 1: ...erstanding the manual and receiving proper training is a misuse of this equipment Obtain safety information at tft com serial number This equipment is intended for use by trained and qualified emergen...

Page 2: ...Service Association Inc PO Box 147 Lynn eld MA 01940 www FEMSA org 2020 FEMSA All Rights Reserved PERSONAL RESPONSIBILITY CODE DANGER SUPPORTING MATERIALS The following document contains supporting s...

Page 3: ...e suppression See flow graphs WARNING This equipment is intended for use by trained personnel for firefighting Use of this equipment for other purposes may involve hazards not addressed by this manual...

Page 4: ...anodized MIL 8625 class 3 type 2 stainless steel 300 series nylon 6 6 nitrile rubber Consult factory for higher pressure applications ELECTRICAL Nominal Operating Voltage 12 or 24 VDC auto sense Motor...

Page 5: ...ugh low flow patterns and high flow patterns The nozzle can be operated manually by turning the SHAPER clockwise as seen from the operating position behind the nozzle to move to the straight stream po...

Page 6: ...USH position Doing this prevents unintentional flushing of the nozzle which causes reduced reach and increased flow rate potentially depleting the water supply more quickly NOTICE Turning the shaper f...

Page 7: ...by someone else THIS IS A LIMITED EXPRESS WARRANTY ONLY TFT EXPRESSLY DISCLAIMS WITH RESPECT TO THE EQUIPMENT ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR A PAR...

Page 8: ...ned to the factory for service and testing 11 0 EXPLODED VIEWS AND PARTS LISTS Exploded views and parts lists are available at tft com serial number 12 0 OPERATION AND INSPECTION CHECKLIST BEFORE EACH...