LIE-100 January 14, 2019 Rev00

MANUAL: SHO-FLOW

®

Flow Meter Operations

INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE

WARNING

Understand manual before use. Operation of this device without understanding the manual and 
receiving  proper  training  is  a  misuse  of  this  equipment.  Obtain  safety  information  at  tft.com/
serial-number.

This instruction manual is intended to familiarize fi refi ghters and maintenance personnel with the operation, servicing and 
safety procedures associated with SHO-FLOW fl ow meters.
This manual should be kept available to all operating and maintenance personnel.

TASK FORCE TIPS LLC

MADE IN USA • TFT.com

3701 Innovation Way, Valparaiso, IN 46383-9327 USA

800-348-2686 • 219-462-6161 • Fax 219-464-7155

Summary of Contents for SHO-FLOW Series

Page 1: ...ining is a misuse of this equipment Obtain safety information at tft com serial number This instruction manual is intended to familiarize re ghters and maintenance personnel with the operation servici...

Page 2: ...be called upon to use 4 It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to use 5 It is yo...

Page 3: ...result in minor or moderate injury NOTICE NOTICE is used to address practices not related to personal injury 2 0 SAFETY WARNING The device may be damaged if frozen while containing signi cant amounts...

Page 4: ...n ow stops An arrow indicates the direction of ow The SHO FLOW is intended for intermittent use with clean re water or solutions of water and foam concentrate It is not intended for use with pure foam...

Page 5: ...sure Units PSI BAR KPA 3 3 DEVICE COUPLINGS The SHO FLOW is o ered with standard hose threaded connections 1 5 9 NH 1 5 11 BSP or 1 5 11 5 NPSH Inlets are rigid female threaded couplings Fluid is seal...

Page 6: ...is used to notify the user of the current ow rate in the hose line in real time when a SHO FLOW is connected Whenever the app is opened this screen will open as default 1 To access this screen press...

Page 7: ...owing methods Press the Unpair button on the Wireless Connection page Completely close the app 1 To access this screen press the Menu button 2 Then press the Wireless Connection button 5 3 ESTABLISHI...

Page 8: ...t LPM Both GPM LPM LPS Select the Pressure Units to show for calibration PSI BAR KPA 5 4 SETTINGS The Settings screen is used to con gure the app display using the desired ow units along with setting...

Page 9: ...ith an auxiliary battery which can be used to extend Bluetooth connection times A standard non rechargeable lithium ion battery with a 10 year storage lifespan is software defaulted in the disabled co...

Page 10: ...event of incorrect readings The SHO FLOW is shipped from the factory calibrated Calibration is not required under normal circumstances If you wish to return to this screen press the Menu button Then...

Page 11: ...limited warranty cannot be reasonably cured by repair or replacement TFT may elect to refund the purchase price of the equipment less reasonable depreciation in complete discharge of its obligations u...

Page 12: ...There are no broken or missing parts 2 There is no damage to the device that could impair safe operation e g dents cracks corrosion or other defects 3 The thread and gasket is in good condition 4 The...