9.3 IMPULSE TRIGGER VALVE LUBRICATION
1. Insert tube from BreakFree into drain hole in pistol grip.
2. With nozzle upside down spray a 2 second burst into the pistol grip.
Holding a rag around the tube here can help keep excess BreakFree
from the outside of the nozzle.
3. Keep nozzle upside down for at least 10 seconds to allow the BreakFree
to flow into the valve area.
4. Check for smooth and free operation of the trigger. Repeat a second
time if needed.
IF THIS PROCEDURE DOES NOT RESTORE SMOOTH OPERATION OF THE IMPULSE TRIGGER SYSTEM,
THEN FACTORY SERVICE IS NEEDED. • 24-HOUR HOT LINE — 800-348-2686 • tft.com
9.4 SERVICE TESTING
In accordance with NFPA 1962, equipment must be tested a minimum of annually. Units failing any part of this test must be removed
from service, repaired and retested upon completion of the repair.
9.5 REPAIR
Factory service is available with repair time seldom exceeding one day in our facility. Factory serviced equipment is repaired by
experienced technicians, wet tested to original specifications, and promptly returned. Any returns should include a note as to the nature
of the problem and whom to reach in case of questions.
Repair parts and service procedures are available for those wishing to perform their own repairs. Task Force Tips assumes no liability for
damage to equipment or injury to personnel that is a result of user service. Contact the factory or visit the web site at tft.com for parts
lists, exploded views, test procedures and troubleshooting guides.
Performance tests shall be conducted on the equipment after a repair, or anytime a problem is reported to verify operation in accordance
with TFT test procedures. Consult factory for the procedure that corresponds to the model and serial number of the equipment. Any
equipment which fails the related test criteria should be removed from service immediately. Troubleshooting guides are available with
each test procedure or equipment can be returned to the factory for service and testing.
10.0 EXPLODED VIEWS AND PART LISTS
Exploded views and parts lists are available at tft.com/serial-number.
CAUTION
Any alterations to the product or its markings could diminish safety and constitutes a misuse of
this product.
NOTICE
All replacement parts must be obtained from the manufacturer to assure proper operation of the
device.