TASI 632 Operating Instructions Download Page 1

1

2

OPERATING INSTRUCTIONS 

 

LIGHT METER 

 

 

USB & DC Power   

 Wireless

 

 

USB & DC Power & Wireless 

 

 

 
 
DESCRIPTION

 

This instrument is a portable easy use, compact-sized 

digital lightmeter designed for simple one hand operation. 
Provides selected the lux and fc units. Meter with Backlit 
LCD display, PEAK (50mS pulse light) and HOLD feature. 
Auto range or manual range selected. 
 

 

WARNING 

• To avoid electric shock, do not operate this product in 

wet or damp conditions. 

• To avoid injury or fire hazard, do not operate this prod-

uct in an explosive atmosphere. 

• To avoid eye injury, wear eye protection if there is a 

possibility of exposure to high-intensity rays. 

• Do not immerse in liquids, clean the sensor head using 

only a damp cloth. 

• Cover sensor head when not in use to extend silicon 

photodiode sensor life.

 

 

 

FEDERAL COMMUNICATIONS COMMISSION

 

This device complies with Part 15 of the FCC Rules. 
Operation is subject to the following two conditions:(1) 
this device may not cause harmful interference, and (2) 
this device must accept any interference received, in-
cluding interference that may cause undesired operation.
 

NOTE 

This equipment has been tested and found to comply 
with the limits for a Class B digital device, pursuant to 
Part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection. This equipment gener-
ates, uses and can radiated radio frequency energy and, 
if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio commu-
nications. However, there is no guarantee that interfer-
ence will not occur in a particular installation If this 
equipment does cause harmful interference to radio or 
television reception, which can be determined by turn-
ing the equipment off and on, the user is encouraged to 
try to correct the interference by one or more of the fol-
lowing measures: 
 
- Reorient or relocate the receiving antenna. 
- Increase the separation between the equipment and 

receiver. 

- Connect the equipment into an outlet on a circuit dif-

ferent from that to which the receiver is connected. 

- Consult the dealer or an experienced radio/TV techni-

cian for help. 

 
Shielded interface cables must be used in order to com-
ply with emission limits. 
 
Changes or modifications not expressly approved by the 
party responsible for compliance could void the user‘s 
authority to operate the equipment. 

 

WIRELESS NOTE 

Wireless receiver must keep a distance at least 40cm 

from the meter and meter to meter distance 

must be at least 30cm. 

 

GENERAL 

Operating environment: 

0°C to 50°C at < 80%R.H. 

Storage temperature: 

-20°C to 50°C, 0 to 80% R.H. 

with battery removed from meter. 

 

Low battery indication:

 The “

” is displayed when 

the battery voltage drops below the operating level.   

Battery: 

1.5V X 4 pcs AAA size. 

Battery Life: 

200 hours with low battery indicator 

on display. 

Auto power off: 

15 minutes, press power key to resume 

operation. 

Dimensions: 

170mm(H) x 44mm(W) x 40mm(D).   

Weight:

 Approx. 200g including batteries(1.5Vx4pcs 

AAA size). 

Back Side: 

632A/632C

 

1. USB Port 
2. DC power JACK(12V) 

 

SPECIFICATIONS 

Units:

 lux, fc 

Range:

 20lux, 200lux, 2000lux, 20000lux, 200000lux, 

20fc, 200fc, 2000fc, 20000fc 

Resolution: 

0.01lux, 0.001fc

 

Spectral response: 

CIE photopic.

 

Total accuracy for CIE standard illuminant A 

(2856K): 

±(3%rdg + 10dgts) 

Accuracy: 

Stated accuracy at 23°C±5°C, <70% R.H. 

Temperature Coefficient:   

±10% of specified accuracy/°C change when tempera-
ture is out of the range between 18°C~28°C 
(64.4°F~82.4°F). 

Measurement rate: 

1 times/second. 

 

CIE Photopic Standard: 

The CIE photopic curve is an international standard 
for the color response of the average human eyes. 

 

Spectral accuracy: 

ƒ'1<8% 

Acceptance angle: 

ƒ'

2

<2% cosine corrected (150°) 

Total accuracy for CIE standard illuminant A (2856K): 

±(3.0%rdg + 10dgts) 

CIE standard illuminant A can be realized by means 
of CIE standard source A, which is defined as: A 
gas-filled tungsten-filament lamp operating at a cor-
related colour temperature of 2856K 

 

OPERATING INSTRUCTIONS 

1. “

” Button: 

When the power is off, press “

” key to turn on  the 

meter. In the MAX/MIN recording mode, power off 
function was disabled, unless exiting MAX/MIN mode. 

 

2. “lux/fc” Button: 

Press “lux/fc” key to change lux or fc unit. 
10.764·footcandles = lux (lumens/meter2). 
0.0929·lux = footcandles (lumens/foot2). 

 

3. “ ” Button: 

Press “ ” key to trigger on the backlight function, 
press the “ ” button again to cancel the backlight 
function. The backlight will switch-off automatically 
after 30 seconds. 
 

4. “PEAK” Button: 

Press “PEAK” key may toggle to show peak measure-
ment and “

P

” was shown on display.   

Peak response time: > 50mS pulse light. 
 

5. “MAX/MIN (

)” Button: 

Press “MIN/MAX” key to enter the “MIN/MAX” re-
cording mode and REC shows on the display. Press the 

“MIN/MAX” key again to rotate through the current 
readings: 
MAX: The highest measurement recorded. 
MIN: The lowest measurement recorded. 
AVG: The average values of the measurements. 
 
Pressing MIN/MAX button over two seconds to exit the 
function. 
In this mode, the APO function and other buttons are 
disabled, excluding “HOLD” and Back-light buttons. 
Press and hold down the “MAX/MIN” button for more 
than 2 seconds to exit the MAX/MIN function. 
 

6. “HOLD” Button: 

Press the “HOLD” button to enter the data hold mode, 
the “H” indicator was displayed at the left of display. 
When data hold mode is selected, the meter held the 
present readings and stops all further measurements. 
Press the “HOLD” button again to cancel data hold 
mode, and resume measuring. 
In “MIN/MAX” mode, press “HOLD” button to stop 
recording, all values are frozen, press “HOLD” button 
again to restart recording. 
 

7. “ZERO” Button: 

Press “ZERO” key to zero adjustment for immediate 
measurement, before the adjustment, must cover the cap. 
Zero adjustment function can be calibrated only in the 
20lux and 20fc range, the adjustment range for 0 
±50dgt. 

8. “SAVE (

)“ Button: 

The function saves the lux or fc data in memory. Press 
the “SAVE” key to save the current data, the symbol 
“MEM” is displayed to indicate the data are saved. 
There are 128 data could be recorded into memory and 
displayed on the top-right LCD. 
 

9. “RANGE” Button: 

Press “RANGE” button to select the manual range 
mode ,and turn off the “AUTO” indicator. In the Man-
ual Range mode, press “RANGE” button to switch the 
range 20lux, 200lux, 2000lux, 20000lux, 200000lux, 
or 20fc, 200fc, 2000fc, 20000fc in sequence and a new 
range value is displayed. Hold “RANGE” button for 2 
seconds to exit the Manual Range mode, and back to 
Auto-range. 
 

10. “>5S CLR” Button: 

Press “> 5S CLR” key and hold for 5 seconds to clear 
the data in the memory, the “MEM” and “Clr” indicator 
is displayed at upper-right LCD . 
 

11. “RECALL” Button: 

Press “RECALL” key to enter READ Mode, the 
“MEM” indicator is displayed at upper-right corner. 
Press “

” or “

” key to review the recorded data. 

Press and hold down the “RECALL” key for more than 
2 seconds to exit the RECALL function. 

 

632
632A
632B

 

632C

 

632

TASI