16 – Parameter tables
Sonicview 16/24 Mixer Basic Parameters
Libraries
Name
User
Preset
Snapshot
128
1
MODULE INPUT
128
2
MODULE FX RTN
128
4
MODULE OUTPUT
128
1
EQ
128
18
GEQ
128
0
GATE/EXP/DE-ESSER
128
11
COMP/DUCKER
128
12
FX
128
14
Input Modules
Function
Parameter
steps
Fine Step
(when LCD knob
turned without being
pressed)
Coarse Steps
(when LCD knob
turned while being
pressed)
Pre Amp
Analog Gain
When Analog Reference Level = +6 dBu
When PAD OFF: +12 dB – +66 dB
When PAD ON: −8 dB – +46 dB
When Analog Reference Level = +4 dBu
When PAD OFF: +3 dB – +57 dB
When PAD ON: −17 dB – +37 dB
When Analog Reference Level = 0 dBu
When PAD OFF: +8 dB – +62 dB
When PAD ON: −12 dB – +42 dB
55
1 dB/click
2 dB/click
PAD
OFF/ON
Phantom
OFF/ON
OSC INPUT
OFF/ON
Phase Sw
Normal/Reverse
D.TRIM
-50.0 dB - +20.0 dB
141
0.5 dB/click
2.0 dB/click
HPF
Switch
OFF/ON
Freq
20 Hz - 1.0 kHz
69
1 point/click
1/12 oct/click
3 step/click
1/4 oct/click
DIRECT OUT
Direct Out Switch
OFF/ON
Direct Out Point
INPUT/POST HPF/POST FADER
Direct Out Trim
-20.0 dB - +20.0 dB
401
0.1 dB/click
2.0 dB/click
INSERT
Switch
OFF/ON
Insert Point
PRE EQ/PRE FADER
GATE/EXP/DE-
ESSER
Dynamics1 Switch
OFF/ON
Dynamics1 Type
GATE/EXPANDER/DE-ESSER
GATE
Gate Threshold
-80 dB - 0 dB
81
1 dB/click
4 dB/click
Gate Range
-60 dB - 0 dB
61
1 dB/click
3 dB/click
Gate Attack
0 ms - 125 ms
126
1 ms/click
5 ms/click
Gate Hold
0 ms - 990 ms
100
10 ms/click
50 ms/click
Gate Decay
5 ms - 5.00 s
100
1 point/click
5 point/click
176